WEKO3
アイテム
{"_buckets": {"deposit": "bd4d4161-fc1c-4250-86f3-e48289e3bd46"}, "_deposit": {"created_by": 1, "id": "65766", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "65766"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00065766", "sets": ["29"]}, "author_link": ["647815", "647819", "647816", "647822", "647806", "647820", "647805", "647818", "647823", "647817", "647803", "647813", "647808", "647809", "647824", "647810", "647811", "647812", "647821", "647807", "647814", "647804"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2014-11-06", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "医薬品製造においては薬物の交差汚染等を防止するために製造設備等の洗浄作業が重要であり、共用している設備等については洗浄バリデーションが必要である。洗浄バリデーションは品質管理や安全性確保の観点からも重要であり、評価法として拭き取り法やリンス法等がある。我々は11C標識薬剤の製造を日本核医学会GMPに適応させるために11C標識自動合成装置の洗浄バリデーションについて検討した。交差汚染が考えられる調剤部品を含めた合成装置、分取HPLCシステムの洗浄手順を確定し、洗浄後のリンス液中の原料と主成分(標品)の残存量についてHPLC分析を行った。合成装置では、アセトン、注射用水、消毒用エタノールで洗浄し、検出限界以下(原料0.003 ppm以下、標品0.016 ppm以下)の残存量であった。分取HPLCシステムでは、70-100%アセトニトリル水溶液(4 mL/min、約1時間)で洗浄し、検出限界以下の残存量であった。洗浄バリデーションにより合成装置と分取HPLCシステムの交差汚染をなくし、より高い安全性を担保した11C標識薬剤を臨床へ提供している。", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第54回日本核医学会学術総会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "河村, 和紀"}], "nameIdentifiers": [{"nameIdentifier": "647803", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武井, 誠"}], "nameIdentifiers": [{"nameIdentifier": "647804", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古塚, 賢士"}], "nameIdentifiers": [{"nameIdentifier": "647805", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "橋本, 裕輝"}], "nameIdentifiers": [{"nameIdentifier": "647806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "潮見, 聡"}], "nameIdentifiers": [{"nameIdentifier": "647807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤代, 智也"}], "nameIdentifiers": [{"nameIdentifier": "647808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金子, いづみ"}], "nameIdentifiers": [{"nameIdentifier": "647809", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩隈, 佳寿子"}], "nameIdentifiers": [{"nameIdentifier": "647810", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "脇, 厚生"}], "nameIdentifiers": [{"nameIdentifier": "647811", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤林, 康久"}], "nameIdentifiers": [{"nameIdentifier": "647812", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張, 明栄"}], "nameIdentifiers": [{"nameIdentifier": "647813", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河村 和紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647814", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武井 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647815", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古塚 賢士", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647816", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "橋本 裕輝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647817", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "潮見 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647818", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤代 智也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647819", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金子 いづみ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647820", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩隈 佳寿子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647821", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "脇 厚生", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647822", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤林 康久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647823", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 明栄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "647824", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "11C標識自動合成装置と分取HPLCシステムの洗浄バリデーションの検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "11C標識自動合成装置と分取HPLCシステムの洗浄バリデーションの検討"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/65766", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-09-28"}, "publish_date": "2015-09-28", "publish_status": "0", "recid": "65766", "relation": {}, "relation_version_is_last": true, "title": ["11C標識自動合成装置と分取HPLCシステムの洗浄バリデーションの検討"], "weko_shared_id": -1}
11C標識自動合成装置と分取HPLCシステムの洗浄バリデーションの検討
https://repo.qst.go.jp/records/65766
https://repo.qst.go.jp/records/65766187a30e8-6400-4da3-a2bb-d4a2ed4d5b85
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-09-28 | |||||
タイトル | ||||||
タイトル | 11C標識自動合成装置と分取HPLCシステムの洗浄バリデーションの検討 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
河村, 和紀
× 河村, 和紀× 武井, 誠× 古塚, 賢士× 橋本, 裕輝× 潮見, 聡× 藤代, 智也× 金子, いづみ× 岩隈, 佳寿子× 脇, 厚生× 藤林, 康久× 張, 明栄× 河村 和紀× 武井 誠× 古塚 賢士× 橋本 裕輝× 潮見 聡× 藤代 智也× 金子 いづみ× 岩隈 佳寿子× 脇 厚生× 藤林 康久× 張 明栄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 医薬品製造においては薬物の交差汚染等を防止するために製造設備等の洗浄作業が重要であり、共用している設備等については洗浄バリデーションが必要である。洗浄バリデーションは品質管理や安全性確保の観点からも重要であり、評価法として拭き取り法やリンス法等がある。我々は11C標識薬剤の製造を日本核医学会GMPに適応させるために11C標識自動合成装置の洗浄バリデーションについて検討した。交差汚染が考えられる調剤部品を含めた合成装置、分取HPLCシステムの洗浄手順を確定し、洗浄後のリンス液中の原料と主成分(標品)の残存量についてHPLC分析を行った。合成装置では、アセトン、注射用水、消毒用エタノールで洗浄し、検出限界以下(原料0.003 ppm以下、標品0.016 ppm以下)の残存量であった。分取HPLCシステムでは、70-100%アセトニトリル水溶液(4 mL/min、約1時間)で洗浄し、検出限界以下の残存量であった。洗浄バリデーションにより合成装置と分取HPLCシステムの交差汚染をなくし、より高い安全性を担保した11C標識薬剤を臨床へ提供している。 | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第54回日本核医学会学術総会 | |||||
発表年月日 | ||||||
日付 | 2014-11-06 | |||||
日付タイプ | Issued |