WEKO3
アイテム
{"_buckets": {"deposit": "ade08a54-5222-4fb5-a752-dd006075f99f"}, "_deposit": {"created_by": 1, "id": "59419", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "59419"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00059419", "sets": ["29"]}, "author_link": ["591393", "591399", "591394", "591398", "591397", "591396", "591395", "591392"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2002-10-11", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "放射線医学総合研究所では、micro beam Scanning PIXE analysis lineにおけるビームサイズを確認するために、PIXEとScanning Transmission Ion Microscopy (STIM)を用いている。今回、direct STIMによる位置分解能の測定結果と、CR39を用いたmicro beamの観測結果について報告する。", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第19回", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "591392", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯川, 雅枝"}], "nameIdentifiers": [{"nameIdentifier": "591393", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "591394", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "591395", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "591396", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯川 雅枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "591397", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "591398", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "591399", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "MicroBeamscanningPIXEにおけるDirectSTIMを用いた位置分解能の試み", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "MicroBeamscanningPIXEにおけるDirectSTIMを用いた位置分解能の試み"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/59419", "pubdate": {"attribute_name": "公開日", "attribute_value": "2002-10-24"}, "publish_date": "2002-10-24", "publish_status": "0", "recid": "59419", "relation": {}, "relation_version_is_last": true, "title": ["MicroBeamscanningPIXEにおけるDirectSTIMを用いた位置分解能の試み"], "weko_shared_id": -1}
MicroBeamscanningPIXEにおけるDirectSTIMを用いた位置分解能の試み
https://repo.qst.go.jp/records/59419
https://repo.qst.go.jp/records/594199442c526-531f-4f3c-809d-6bee78512523
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2002-10-24 | |||||
タイトル | ||||||
タイトル | MicroBeamscanningPIXEにおけるDirectSTIMを用いた位置分解能の試み | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
今関, 等
× 今関, 等× 湯川, 雅枝× 石川, 剛弘× 濱野, 毅× 今関 等× 湯川 雅枝× 石川 剛弘× 濱野 毅 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 放射線医学総合研究所では、micro beam Scanning PIXE analysis lineにおけるビームサイズを確認するために、PIXEとScanning Transmission Ion Microscopy (STIM)を用いている。今回、direct STIMによる位置分解能の測定結果と、CR39を用いたmicro beamの観測結果について報告する。 | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第19回 | |||||
発表年月日 | ||||||
日付 | 2002-10-11 | |||||
日付タイプ | Issued |