{"_buckets": {"deposit": "a5a09307-89a9-4af6-8539-e6f70bc97aff"}, "_deposit": {"created_by": 1, "id": "58846", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "58846"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00058846", "sets": ["11"]}, "author_link": ["586668", "586667", "586664", "586662", "586669", "586663", "586665", "586666"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "47", "bibliographicPageStart": "44", "bibliographic_titles": [{"bibliographic_title": "クリーンエネルギー"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "熱化学水素製造ISプロセスの一工程であるブンゼン反応(2H2O+SO2+I2→H2SO4+2HI)の熱効率向上を目指し、カチオン交換膜を用いた専用のブンゼン反応器を開発した。放射線グラフト重合法で作製したカチオン交換膜を用いてブンゼン反応試験を行ったとき、既存の市販膜の場合よりも反応過電圧を低減できた。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "野村幹弘"}], "nameIdentifiers": [{"nameIdentifier": "586662", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今林慎一郎"}], "nameIdentifiers": [{"nameIdentifier": "586663", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澤田, 真一"}], "nameIdentifiers": [{"nameIdentifier": "586664", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "八巻, 徹也"}], "nameIdentifiers": [{"nameIdentifier": "586665", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田中伸幸"}], "nameIdentifiers": [{"nameIdentifier": "586666", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "久保真治"}], "nameIdentifiers": [{"nameIdentifier": "586667", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澤田 真一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586668", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "八巻 徹也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586669", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/58846", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-03-22"}, "publish_date": "2018-03-22", "publish_status": "0", "recid": "58846", "relation": {}, "relation_version_is_last": true, "title": ["高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発"], "weko_shared_id": -1}
高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発
https://repo.qst.go.jp/records/58846
https://repo.qst.go.jp/records/5884698757604-0ca8-491a-b717-654c25f6db06
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-22 | |||||
タイトル | ||||||
タイトル | 高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
野村幹弘
× 野村幹弘× 今林慎一郎× 澤田, 真一× 八巻, 徹也× 田中伸幸× 久保真治× 澤田 真一× 八巻 徹也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 熱化学水素製造ISプロセスの一工程であるブンゼン反応(2H2O+SO2+I2→H2SO4+2HI)の熱効率向上を目指し、カチオン交換膜を用いた専用のブンゼン反応器を開発した。放射線グラフト重合法で作製したカチオン交換膜を用いてブンゼン反応試験を行ったとき、既存の市販膜の場合よりも反応過電圧を低減できた。 | |||||
書誌情報 |
クリーンエネルギー p. 44-47, 発行日 2017-08 |