WEKO3
アイテム
{"_buckets": {"deposit": "a0ebd0e8-553d-440c-93bd-c141288341bf"}, "_deposit": {"created_by": 1, "id": "57890", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "57890"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00057890", "sets": ["11"]}, "author_link": ["582351", "582348", "582346", "582353", "582347", "582349", "582352", "582356", "582354", "582355", "582350"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "07", "bibliographicPageStart": "000", "bibliographicVolumeNumber": "53", "bibliographic_titles": [{"bibliographic_title": "放射線科学"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "2009年夏、HIMACの治療室及びシミュレーション室において、X線撮像装置を従来のImage Intensifier (I.I管)から半導体Flat Panel Detector (FPD)に変更し、9月から全室での臨床運用を開始した。またFPD画像の高分解能の特長を活かすために、新たな位置決め用ソフトを開発し、患者位置決めシステムの大幅な更新をおこなった。本報告では、FPD導入並びに位置決めシステムの更新による運用状況について述べる。", "subitem_description_type": "Abstract"}]}, "item_10004_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0441-2540", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "熊谷, 忠房"}], "nameIdentifiers": [{"nameIdentifier": "582346", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蓑原, 伸一"}], "nameIdentifiers": [{"nameIdentifier": "582347", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田, 茂一"}], "nameIdentifiers": [{"nameIdentifier": "582348", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "新田, 和範"}], "nameIdentifiers": [{"nameIdentifier": "582349", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金野, 正裕"}], "nameIdentifiers": [{"nameIdentifier": "582350", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "582351", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "熊谷 忠房", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "582352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蓑原 伸一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "582353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田 茂一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "582354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "新田 和範", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "582355", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金野 正裕", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "582356", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X線FPDを用いた患者位置決めシステムの運用報告", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X線FPDを用いた患者位置決めシステムの運用報告"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/57890", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-04-29"}, "publish_date": "2011-04-29", "publish_status": "0", "recid": "57890", "relation": {}, "relation_version_is_last": true, "title": ["X線FPDを用いた患者位置決めシステムの運用報告"], "weko_shared_id": -1}
X線FPDを用いた患者位置決めシステムの運用報告
https://repo.qst.go.jp/records/57890
https://repo.qst.go.jp/records/57890eb2535d5-c8df-47b8-8092-21fa7350abe1
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-04-29 | |||||
タイトル | ||||||
タイトル | X線FPDを用いた患者位置決めシステムの運用報告 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
熊谷, 忠房
× 熊谷, 忠房× 蓑原, 伸一× 福田, 茂一× 新田, 和範× 金野, 正裕× その他× 熊谷 忠房× 蓑原 伸一× 福田 茂一× 新田 和範× 金野 正裕 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 2009年夏、HIMACの治療室及びシミュレーション室において、X線撮像装置を従来のImage Intensifier (I.I管)から半導体Flat Panel Detector (FPD)に変更し、9月から全室での臨床運用を開始した。またFPD画像の高分解能の特長を活かすために、新たな位置決め用ソフトを開発し、患者位置決めシステムの大幅な更新をおこなった。本報告では、FPD導入並びに位置決めシステムの更新による運用状況について述べる。 | |||||
書誌情報 |
放射線科学 巻 53, 号 07, p. 000, 発行日 2010-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0441-2540 |