WEKO3
アイテム
{"_buckets": {"deposit": "285187d8-2726-4a34-9567-88212c4e0d19"}, "_deposit": {"created_by": 1, "id": "55919", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55919"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055919", "sets": ["7"]}, "author_link": ["572176", "572171", "572174", "572175", "572173", "572172"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "49", "bibliographicPageStart": "43", "bibliographicVolumeNumber": "8", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書 Vol. 8 、March 2014"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The neutron exposure accelerator system for biological effect experiments (NASBEE)[1] installed in the low dose radiation effects research building of the National Institute of Radiological Sciences (NIRS) in Japan generates neutrons from a beryllium target by deuterium beam irradiation from a predominantly 2 MV tandem accelerator. There are two separate irradiation rooms, one being a conventional room for studies in biology and physics, another for the irradiation of mice, rats, etc., in a Specific Pathogen Free (SPF) environment. Since the open for research use in 2003, the system has been used by many researchers both from within and outside of the institute. The ion source is a multicusp ion source, using deuterium and hydrogen gas, it can output 500 µA deuteron beams and 1mA proton beams respectively from the ion source outlet. In this report, we introduce the features of this equipment, as well as explain some of the troubles that have occurred around the ion source.", "subitem_description_type": "Abstract"}]}, "item_10004_relation_10": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "978-4-938987-89-3", "subitem_relation_type_select": "ISBN"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "572171", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田充"}], "nameIdentifiers": [{"nameIdentifier": "572172", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "萩原拓也"}], "nameIdentifiers": [{"nameIdentifier": "572173", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白川, 芳幸"}], "nameIdentifiers": [{"nameIdentifier": "572174", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "572175", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白川 芳幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "572176", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "中性子線照射装置(NASBEE)の現状2013", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "中性子線照射装置(NASBEE)の現状2013"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55919", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-12-08"}, "publish_date": "2014-12-08", "publish_status": "0", "recid": "55919", "relation": {}, "relation_version_is_last": true, "title": ["中性子線照射装置(NASBEE)の現状2013"], "weko_shared_id": -1}
中性子線照射装置(NASBEE)の現状2013
https://repo.qst.go.jp/records/55919
https://repo.qst.go.jp/records/55919f84c040a-1d82-4706-b622-92ccd0e23de6
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-12-08 | |||||
タイトル | ||||||
タイトル | 中性子線照射装置(NASBEE)の現状2013 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
酢屋, 徳啓
× 酢屋, 徳啓× 須田充× 萩原拓也× 白川, 芳幸× 酢屋 徳啓× 白川 芳幸 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The neutron exposure accelerator system for biological effect experiments (NASBEE)[1] installed in the low dose radiation effects research building of the National Institute of Radiological Sciences (NIRS) in Japan generates neutrons from a beryllium target by deuterium beam irradiation from a predominantly 2 MV tandem accelerator. There are two separate irradiation rooms, one being a conventional room for studies in biology and physics, another for the irradiation of mice, rats, etc., in a Specific Pathogen Free (SPF) environment. Since the open for research use in 2003, the system has been used by many researchers both from within and outside of the institute. The ion source is a multicusp ion source, using deuterium and hydrogen gas, it can output 500 µA deuteron beams and 1mA proton beams respectively from the ion source outlet. In this report, we introduce the features of this equipment, as well as explain some of the troubles that have occurred around the ion source. | |||||
書誌情報 |
放射線医学総合研究所技術報告書 Vol. 8 、March 2014 巻 8, p. 43-49, 発行日 2014-03 |
|||||
ISBN | ||||||
識別子タイプ | ISBN | |||||
関連識別子 | 978-4-938987-89-3 |