WEKO3
アイテム
{"_buckets": {"deposit": "942ee786-cf51-42cd-a71e-6da85c5f1268"}, "_deposit": {"created_by": 1, "id": "55633", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55633"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055633", "sets": ["7"]}, "author_link": ["569258", "569260", "569256", "569261", "569267", "569264", "569254", "569257", "569265", "569262", "569266", "569263", "569255", "569259"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "61", "bibliographicPageStart": "56", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "放医研のX線棟の標準線源室では、ガンマ線に対する検出器の校正試験だけではなく、低線量率での生物試実験が行われている。目的にあった線量率の場を決めるためにスタンド型ガンマ線照射装置の137Csを用いて標準線源室の各場所での線量率測定を行った。照射室内の位置、および、鉛板を吸収体として使用することで、137Cs線源で、約0.05〜100 mGy/hourの線量率での照射が可能である", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "海老澤, 悟"}], "nameIdentifiers": [{"nameIdentifier": "569254", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村, 尚"}], "nameIdentifiers": [{"nameIdentifier": "569255", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "569256", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "569257", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "569258", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野, 裕之"}], "nameIdentifiers": [{"nameIdentifier": "569259", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井, 大輔"}], "nameIdentifiers": [{"nameIdentifier": "569260", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "海老澤 悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569261", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569262", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569263", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569264", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569265", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野 裕之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569266", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井 大輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569267", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X線棟標準線源室における線量率の空間分布", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X線棟標準線源室における線量率の空間分布"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55633", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-11-25"}, "publish_date": "2008-11-25", "publish_status": "0", "recid": "55633", "relation": {}, "relation_version_is_last": true, "title": ["X線棟標準線源室における線量率の空間分布"], "weko_shared_id": -1}
X線棟標準線源室における線量率の空間分布
https://repo.qst.go.jp/records/55633
https://repo.qst.go.jp/records/556330bade31d-d7b4-4127-92c7-9ff4ea72d7ba
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-11-25 | |||||
タイトル | ||||||
タイトル | X線棟標準線源室における線量率の空間分布 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
海老澤, 悟
× 海老澤, 悟× 北村, 尚× 石川, 剛弘× 今関, 等× 酢屋, 徳啓× 高野, 裕之× 三井, 大輔× 海老澤 悟× 北村 尚× 石川 剛弘× 今関 等× 酢屋 徳啓× 高野 裕之× 三井 大輔 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 放医研のX線棟の標準線源室では、ガンマ線に対する検出器の校正試験だけではなく、低線量率での生物試実験が行われている。目的にあった線量率の場を決めるためにスタンド型ガンマ線照射装置の137Csを用いて標準線源室の各場所での線量率測定を行った。照射室内の位置、および、鉛板を吸収体として使用することで、137Cs線源で、約0.05〜100 mGy/hourの線量率での照射が可能である | |||||
書誌情報 |
放射線医学総合研究所技術報告書 巻 2, p. 56-61, 発行日 2008-09 |