WEKO3
アイテム
{"_buckets": {"deposit": "2b478242-71f4-4be1-8d91-4943d13ffa68"}, "_deposit": {"created_by": 1, "id": "55592", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55592"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055592", "sets": ["7"]}, "author_link": ["568779", "568780", "568786", "568788", "568787", "568782", "568783", "568784", "568785", "568789", "568781", "568778", "568790"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-205", "bibliographicPageEnd": "7", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "2007", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In order to perform Linear Energy Transfer (LET) measurements for 290 MeV/u carbon beam, used for radiotherapy at the National Institute of Radiological Sciences, we used passive CR-39 Plastic Nuclear Track Detectors. The response curves for two kinds of CR-39s (TD-1 and TNF-1 detectors) were obtained using several species of ions and energies. Detection efficiency and LET resolution of TD-1 for therapeutic carbon ion were measured to be 100% and ~ 1 keV/\u0026#61549;m (FWHM), respectively. Sensitivity degradation in water was confirmed for TD-1 detector.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "安田, 仲宏"}], "nameIdentifiers": [{"nameIdentifier": "568778", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蔵野, 美恵子"}], "nameIdentifiers": [{"nameIdentifier": "568779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宗, 大路"}], "nameIdentifiers": [{"nameIdentifier": "568780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川嶋, 元"}], "nameIdentifiers": [{"nameIdentifier": "568781", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平, 聡"}], "nameIdentifiers": [{"nameIdentifier": "568782", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "落合, 佳子"}], "nameIdentifiers": [{"nameIdentifier": "568783", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "シーバー, レンビット"}], "nameIdentifiers": [{"nameIdentifier": "568784", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 仲宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568785", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蔵野 美恵子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568786", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宗 大路", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568787", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川嶋 元", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568788", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568789", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "落合 佳子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568790", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55592", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-01-08"}, "publish_date": "2008-01-08", "publish_status": "0", "recid": "55592", "relation": {}, "relation_version_is_last": true, "title": ["Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry"], "weko_shared_id": -1}
Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry
https://repo.qst.go.jp/records/55592
https://repo.qst.go.jp/records/55592e4c2f86f-62c2-458f-b792-4f2145bec855
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-01-08 | |||||
タイトル | ||||||
タイトル | Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
安田, 仲宏
× 安田, 仲宏× 蔵野, 美恵子× 宗, 大路× 川嶋, 元× 小平, 聡× 落合, 佳子× シーバー, レンビット× 安田 仲宏× 蔵野 美恵子× 宗 大路× 川嶋 元× 小平 聡× 落合 佳子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to perform Linear Energy Transfer (LET) measurements for 290 MeV/u carbon beam, used for radiotherapy at the National Institute of Radiological Sciences, we used passive CR-39 Plastic Nuclear Track Detectors. The response curves for two kinds of CR-39s (TD-1 and TNF-1 detectors) were obtained using several species of ions and energies. Detection efficiency and LET resolution of TD-1 for therapeutic carbon ion were measured to be 100% and ~ 1 keV/m (FWHM), respectively. Sensitivity degradation in water was confirmed for TD-1 detector. | |||||
書誌情報 |
放射線医学総合研究所技術報告書 巻 2007, 号 NIRS-M-205, p. 1-7, 発行日 2007-10 |