WEKO3
アイテム
{"_buckets": {"deposit": "87e77744-738d-4f67-a591-be0b045b90b2"}, "_deposit": {"created_by": 1, "id": "54693", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54693"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054693", "sets": ["2"]}, "author_link": ["559049", "559058", "559043", "559059", "559035", "559044", "559034", "559048", "559037", "559040", "559060", "559033", "559051", "559050", "559047", "559057", "559056", "559055", "559045", "559046", "559053", "559052", "559054", "559036", "559032", "559038", "559041", "559039", "559042"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "MOP042", "bibliographic_titles": [{"bibliographic_title": "Proceedings of Linear Accelerator Conference (LINAC06)"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A compact injector, designed for a medical accelerator complex, was constructed. It consists of an Electron-Cyclotron-Resonance Ion-Source (ECRIS) and two linacs, which are a Radio-Frequency-Quadrupole (RFQ) linac and an Alternating-Phase-Focused Interdigital H-mode Drift-Tube-Linac (APF IH-DTL) having the same operating frequency of 200 MHz. The compact injector can accelerate carbon ions of 12C4+ up to 4.0 MeV/u. Use of the APF IH-DTL enabled us to design the compact injector; the total length of the two linacs is approximately 6m. After installation of the compact injector, beam acceleration tests were performed. We have succeeded to accelerate carbon ions with satisfactory performance. An overview of the compact injector as well as results of the beam acceleration tests is described.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岩田, 佳之"}], "nameIdentifiers": [{"nameIdentifier": "559032", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤澤, 高志"}], "nameIdentifiers": [{"nameIdentifier": "559033", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條, 悟"}], "nameIdentifiers": [{"nameIdentifier": "559034", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "559035", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上, 健"}], "nameIdentifiers": [{"nameIdentifier": "559036", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松, 正幸"}], "nameIdentifiers": [{"nameIdentifier": "559037", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 博嗣"}], "nameIdentifiers": [{"nameIdentifier": "559038", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本, 幸雄"}], "nameIdentifiers": [{"nameIdentifier": "559039", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 聰"}], "nameIdentifiers": [{"nameIdentifier": "559040", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 和男"}], "nameIdentifiers": [{"nameIdentifier": "559041", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤本, 哲也"}], "nameIdentifiers": [{"nameIdentifier": "559042", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "竹内, 猛"}], "nameIdentifiers": [{"nameIdentifier": "559043", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "密本, 俊典"}], "nameIdentifiers": [{"nameIdentifier": "559044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "筒井, 裕士"}], "nameIdentifiers": [{"nameIdentifier": "559045", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田, 隆正"}], "nameIdentifiers": [{"nameIdentifier": "559046", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺, 崇"}], "nameIdentifiers": [{"nameIdentifier": "559047", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩田 佳之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559048", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤澤 高志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559049", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條 悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559050", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559051", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559052", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559053", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 博嗣", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559054", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本 幸雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 聰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本 和男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "竹内 猛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田 隆正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺 崇", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559060", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "PERFORMANCE OF ALTERNATING-PHASE-FOCUSED IH-DTL", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "PERFORMANCE OF ALTERNATING-PHASE-FOCUSED IH-DTL"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54693", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-01-30"}, "publish_date": "2017-01-30", "publish_status": "0", "recid": "54693", "relation": {}, "relation_version_is_last": true, "title": ["PERFORMANCE OF ALTERNATING-PHASE-FOCUSED IH-DTL"], "weko_shared_id": -1}
PERFORMANCE OF ALTERNATING-PHASE-FOCUSED IH-DTL
https://repo.qst.go.jp/records/54693
https://repo.qst.go.jp/records/54693549122ad-bfaf-4412-a43c-a191499eb8d7
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-01-30 | |||||
タイトル | ||||||
タイトル | PERFORMANCE OF ALTERNATING-PHASE-FOCUSED IH-DTL | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
岩田, 佳之
× 岩田, 佳之× 藤澤, 高志× 北條, 悟× 宮原, 信幸× 村上, 健× 村松, 正幸× 小川, 博嗣× 坂本, 幸雄× 山田, 聰× 山本, 和男× 藤本, 哲也× 竹内, 猛× 密本, 俊典× 筒井, 裕士× 上田, 隆正× 渡辺, 崇× 岩田 佳之× 藤澤 高志× 北條 悟× 宮原 信幸× 村上 健× 村松 正幸× 小川 博嗣× 坂本 幸雄× 山田 聰× 山本 和男× 竹内 猛× 上田 隆正× 渡辺 崇 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A compact injector, designed for a medical accelerator complex, was constructed. It consists of an Electron-Cyclotron-Resonance Ion-Source (ECRIS) and two linacs, which are a Radio-Frequency-Quadrupole (RFQ) linac and an Alternating-Phase-Focused Interdigital H-mode Drift-Tube-Linac (APF IH-DTL) having the same operating frequency of 200 MHz. The compact injector can accelerate carbon ions of 12C4+ up to 4.0 MeV/u. Use of the APF IH-DTL enabled us to design the compact injector; the total length of the two linacs is approximately 6m. After installation of the compact injector, beam acceleration tests were performed. We have succeeded to accelerate carbon ions with satisfactory performance. An overview of the compact injector as well as results of the beam acceleration tests is described. | |||||
書誌情報 |
Proceedings of Linear Accelerator Conference (LINAC06) p. MOP042, 発行日 2006-08 |