WEKO3
アイテム
{"_buckets": {"deposit": "3aaab303-45d1-4784-8048-7435c2e2010c"}, "_deposit": {"created_by": 1, "id": "54692", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54692"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054692", "sets": ["2"]}, "author_link": ["559008", "559017", "559003", "559019", "559030", "559013", "559006", "559016", "559009", "559010", "559027", "559014", "559020", "559031", "559015", "559012", "559025", "559004", "559018", "559022", "559029", "559021", "559028", "559023", "559005", "559011", "559026", "559024", "559007"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "WE204", "bibliographic_titles": [{"bibliographic_title": "Proceedings of Linear Accelerator Conference (LINAC08)"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Compact linacs, consisted of a Radio-Frequency-Quadrupole (RFQ) linac and an Interdigital H-mode Drift-Tube-Linac (IH-DTL) having the same operating frequency of 200 MHz, were designed for an injector of heavy-ion medical synchrotrons. For beam focusing of IH-DTL, the method of Alternating-Phase-Focusing (APF) was applied. The total length of the RFQ linac and the IH-DTL is as short as 6 m. With the two linacs, carbon ions of 12C4+, produced by an ECR Ion-Source (ECRIS), are accelerated to 4.0 MeV/u with the beam intensity of 380 eA. The compact linacs were constructed and installed in NIRS. We have succeeded to accelerate carbon ions with the APF linac for the first time.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岩田, 佳之"}], "nameIdentifiers": [{"nameIdentifier": "559003", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤澤, 高志"}], "nameIdentifiers": [{"nameIdentifier": "559004", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條, 悟"}], "nameIdentifiers": [{"nameIdentifier": "559005", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "559006", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上, 健"}], "nameIdentifiers": [{"nameIdentifier": "559007", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松, 正幸"}], "nameIdentifiers": [{"nameIdentifier": "559008", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 博嗣"}], "nameIdentifiers": [{"nameIdentifier": "559009", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本, 幸雄"}], "nameIdentifiers": [{"nameIdentifier": "559010", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 聰"}], "nameIdentifiers": [{"nameIdentifier": "559011", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 和男"}], "nameIdentifiers": [{"nameIdentifier": "559012", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤本, 哲也"}], "nameIdentifiers": [{"nameIdentifier": "559013", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "竹内, 猛"}], "nameIdentifiers": [{"nameIdentifier": "559014", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "密本, 俊典"}], "nameIdentifiers": [{"nameIdentifier": "559015", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "筒井, 裕士"}], "nameIdentifiers": [{"nameIdentifier": "559016", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田, 隆正"}], "nameIdentifiers": [{"nameIdentifier": "559017", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺, 崇"}], "nameIdentifiers": [{"nameIdentifier": "559018", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩田 佳之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559019", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤澤 高志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559020", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條 悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559021", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559022", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559023", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559024", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 博嗣", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559025", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本 幸雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559026", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 聰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559027", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本 和男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559028", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "竹内 猛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559029", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田 隆正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559030", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺 崇", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "559031", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "IH-DTL AS A COMPACT INJECTOR FOR A HEAVY-ION MEDICAL SYNCHROTRON", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "IH-DTL AS A COMPACT INJECTOR FOR A HEAVY-ION MEDICAL SYNCHROTRON"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54692", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-01-30"}, "publish_date": "2017-01-30", "publish_status": "0", "recid": "54692", "relation": {}, "relation_version_is_last": true, "title": ["IH-DTL AS A COMPACT INJECTOR FOR A HEAVY-ION MEDICAL SYNCHROTRON"], "weko_shared_id": -1}
IH-DTL AS A COMPACT INJECTOR FOR A HEAVY-ION MEDICAL SYNCHROTRON
https://repo.qst.go.jp/records/54692
https://repo.qst.go.jp/records/54692c007469a-184e-491b-9406-d9ac50d9c917
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-01-30 | |||||
タイトル | ||||||
タイトル | IH-DTL AS A COMPACT INJECTOR FOR A HEAVY-ION MEDICAL SYNCHROTRON | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
岩田, 佳之
× 岩田, 佳之× 藤澤, 高志× 北條, 悟× 宮原, 信幸× 村上, 健× 村松, 正幸× 小川, 博嗣× 坂本, 幸雄× 山田, 聰× 山本, 和男× 藤本, 哲也× 竹内, 猛× 密本, 俊典× 筒井, 裕士× 上田, 隆正× 渡辺, 崇× 岩田 佳之× 藤澤 高志× 北條 悟× 宮原 信幸× 村上 健× 村松 正幸× 小川 博嗣× 坂本 幸雄× 山田 聰× 山本 和男× 竹内 猛× 上田 隆正× 渡辺 崇 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Compact linacs, consisted of a Radio-Frequency-Quadrupole (RFQ) linac and an Interdigital H-mode Drift-Tube-Linac (IH-DTL) having the same operating frequency of 200 MHz, were designed for an injector of heavy-ion medical synchrotrons. For beam focusing of IH-DTL, the method of Alternating-Phase-Focusing (APF) was applied. The total length of the RFQ linac and the IH-DTL is as short as 6 m. With the two linacs, carbon ions of 12C4+, produced by an ECR Ion-Source (ECRIS), are accelerated to 4.0 MeV/u with the beam intensity of 380 eA. The compact linacs were constructed and installed in NIRS. We have succeeded to accelerate carbon ions with the APF linac for the first time. | |||||
書誌情報 |
Proceedings of Linear Accelerator Conference (LINAC08) p. WE204, 発行日 2008-09 |