WEKO3
アイテム
{"_buckets": {"deposit": "ad4be719-7b49-4abe-9b67-5c4bb63ac4d3"}, "_deposit": {"created_by": 1, "id": "53791", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53791"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053791", "sets": ["2"]}, "author_link": ["549009", "549010", "549008", "549007"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "2909", "bibliographicPageStart": "2907", "bibliographicVolumeNumber": "10", "bibliographic_titles": [{"bibliographic_title": "EPAC : European Particle Accelerator Conference"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The cooling-stacking injection at the HIMAC synchrotron was used to increase the intensity of Ar18+ ion beam. The beam stacking was realized in a horizontal free\nphase-space, which was created by the HIMAC electron cooler. The stack intensity of (1.5-2.5) / 109 ppp was accumulated at an injection intensity of (0.3-1.0)/109.\nThe lifetime of stack ions is determined by vacuum pressure. The new injected ions were slowly lost at multiple scattering on residual gas atoms at diffusion heating in the vertical direction caused by the acceptance of 30 pi mmmrad and a reduction of cooling force at large betatron amplitudes. The results of numerical simulations and experimental study of cooling-stacking injection on the HIMAC synchrotron are presented.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Syresin, E"}], "nameIdentifiers": [{"nameIdentifier": "549007", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Kouji"}], "nameIdentifiers": [{"nameIdentifier": "549008", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibuya, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "549009", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "549010", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "NUMERICAL AND EXPERIMENTAL STUDY OF COOLING-STACKING INJECTION IN HIMAC SYNCHROTRON", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "NUMERICAL AND EXPERIMENTAL STUDY OF COOLING-STACKING INJECTION IN HIMAC SYNCHROTRON"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53791", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-12-27"}, "publish_date": "2006-12-27", "publish_status": "0", "recid": "53791", "relation": {}, "relation_version_is_last": true, "title": ["NUMERICAL AND EXPERIMENTAL STUDY OF COOLING-STACKING INJECTION IN HIMAC SYNCHROTRON"], "weko_shared_id": -1}
NUMERICAL AND EXPERIMENTAL STUDY OF COOLING-STACKING INJECTION IN HIMAC SYNCHROTRON
https://repo.qst.go.jp/records/53791
https://repo.qst.go.jp/records/53791e2f5ef5f-31e8-4be3-b46c-9bbaa2ceac51
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-27 | |||||
タイトル | ||||||
タイトル | NUMERICAL AND EXPERIMENTAL STUDY OF COOLING-STACKING INJECTION IN HIMAC SYNCHROTRON | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Syresin, E
× Syresin, E× Noda, Kouji× Shibuya, Shinji× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The cooling-stacking injection at the HIMAC synchrotron was used to increase the intensity of Ar18+ ion beam. The beam stacking was realized in a horizontal free phase-space, which was created by the HIMAC electron cooler. The stack intensity of (1.5-2.5) / 109 ppp was accumulated at an injection intensity of (0.3-1.0)/109. The lifetime of stack ions is determined by vacuum pressure. The new injected ions were slowly lost at multiple scattering on residual gas atoms at diffusion heating in the vertical direction caused by the acceptance of 30 pi mmmrad and a reduction of cooling force at large betatron amplitudes. The results of numerical simulations and experimental study of cooling-stacking injection on the HIMAC synchrotron are presented. |
|||||