{"_buckets": {"deposit": "6f59d303-641a-4073-84e7-f4bb2bde76d7"}, "_deposit": {"created_by": 1, "id": "53571", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53571"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053571", "sets": ["2"]}, "author_link": ["546829", "546825", "546823", "546828", "546826", "546824", "546822", "546827"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-07", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "623", "bibliographicPageStart": "621", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "日本加速器学会年会・リニアック技術研究会"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We adjust position and Intensity of beam for treatment every day, which takes about 15 minutes per port for each beam energy. In order to treat more patients with more flexible scheme, we need to minimize the beam tuning time. Therefore, we studied characteristics of beam behavior with present parameters and investigated cause and remedy for daily variation.\nWe found a change of Horizontal tune strangely affects the beam at the treatment room.\n We have changed relevant parameters to enhance reproducibility of beam, report about our investigation and present result of the development.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "白石, 直浩"}], "nameIdentifiers": [{"nameIdentifier": "546822", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "勝間田, 匡"}], "nameIdentifiers": [{"nameIdentifier": "546823", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川, 卓司"}], "nameIdentifiers": [{"nameIdentifier": "546824", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "取越, 正己"}], "nameIdentifiers": [{"nameIdentifier": "546825", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田, 栄一"}], "nameIdentifiers": [{"nameIdentifier": "546826", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546827", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "取越 正己", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546828", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 栄一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "546829", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "HIMACにおける治療ビーム無調整化のための開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "HIMACにおける治療ビーム無調整化のための開発"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53571", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-08-18"}, "publish_date": "2005-08-18", "publish_status": "0", "recid": "53571", "relation": {}, "relation_version_is_last": true, "title": ["HIMACにおける治療ビーム無調整化のための開発"], "weko_shared_id": -1}
HIMACにおける治療ビーム無調整化のための開発
https://repo.qst.go.jp/records/53571
https://repo.qst.go.jp/records/5357136d9eff6-57f1-4cfc-80d3-dff21b0a240c
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-08-18 | |||||
タイトル | ||||||
タイトル | HIMACにおける治療ビーム無調整化のための開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
白石, 直浩
× 白石, 直浩× 勝間田, 匡× 古川, 卓司× 取越, 正己× 高田, 栄一× 古川 卓司× 取越 正己× 高田 栄一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We adjust position and Intensity of beam for treatment every day, which takes about 15 minutes per port for each beam energy. In order to treat more patients with more flexible scheme, we need to minimize the beam tuning time. Therefore, we studied characteristics of beam behavior with present parameters and investigated cause and remedy for daily variation. We found a change of Horizontal tune strangely affects the beam at the treatment room. We have changed relevant parameters to enhance reproducibility of beam, report about our investigation and present result of the development. |
|||||
書誌情報 |
日本加速器学会年会・リニアック技術研究会 巻 2, p. 621-623, 発行日 2005-07 |