WEKO3
アイテム
{"_buckets": {"deposit": "730cb412-41b2-4068-bebd-3a6afae64859"}, "_deposit": {"created_by": 1, "id": "49482", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "49482"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00049482", "sets": ["1"]}, "author_link": ["499751", "499757", "499753", "499756", "499750", "499755", "499754", "499752"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "189", "bibliographicPageStart": "185", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "SPring-8/SACLA利用研究成果集"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "我々は水素貯蔵合金の水素化反応過程の構造変化を放射光その場X線回折測定によって観測するため、新たな試料容器の開発および試験を実施した。ポリイミドチューブを用いた試料容器では 容器自体からBragg反射が生じないため、X線回折用の試料容器として適している。この容器を用いて典型的な水素吸蔵合金の一つであるLaNi4.5Al0.5 は水素化に成功したが、V系BCC合金では水素化が進行しなかった。ポリイミドチューブと同程度の内径のアルミニウム製チューブを用いた容器ではV系BCC合金でも水素化による回折パターンの変化が観測されたため、ポリイミドチューブに問題がある可能性がある。水素貯蔵合金に対する水素化反応過程その場Ⅹ線回折測定にポリイミドチューブを試料容器に用いるには改良が必要である。", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "公益財団法人 高輝度光科学研究センター"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.18957/rr.6.2.185", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2187-6886", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "町田, 晃彦"}], "nameIdentifiers": [{"nameIdentifier": "499750", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "綿貫, 徹"}], "nameIdentifiers": [{"nameIdentifier": "499751", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "榊, 浩司"}], "nameIdentifiers": [{"nameIdentifier": "499752", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kim, Hyunjeong"}], "nameIdentifiers": [{"nameIdentifier": "499753", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "浅野, 耕太"}], "nameIdentifiers": [{"nameIdentifier": "499754", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村, 優美子"}], "nameIdentifiers": [{"nameIdentifier": "499755", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "町田 晃彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "499756", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "綿貫 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "499757", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "水素貯蔵合金の水素ガス圧力下における水素化反応過程その場X線回折測定用の新規試料容器の検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "水素貯蔵合金の水素ガス圧力下における水素化反応過程その場X線回折測定用の新規試料容器の検討"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/49482", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-01-21"}, "publish_date": "2019-01-21", "publish_status": "0", "recid": "49482", "relation": {}, "relation_version_is_last": true, "title": ["水素貯蔵合金の水素ガス圧力下における水素化反応過程その場X線回折測定用の新規試料容器の検討"], "weko_shared_id": -1}
水素貯蔵合金の水素ガス圧力下における水素化反応過程その場X線回折測定用の新規試料容器の検討
https://repo.qst.go.jp/records/49482
https://repo.qst.go.jp/records/49482b537cf96-4c56-456a-ace2-d7bdce005d7d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-01-21 | |||||
タイトル | ||||||
タイトル | 水素貯蔵合金の水素ガス圧力下における水素化反応過程その場X線回折測定用の新規試料容器の検討 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
町田, 晃彦
× 町田, 晃彦× 綿貫, 徹× 榊, 浩司× Kim, Hyunjeong× 浅野, 耕太× 中村, 優美子× 町田 晃彦× 綿貫 徹 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 我々は水素貯蔵合金の水素化反応過程の構造変化を放射光その場X線回折測定によって観測するため、新たな試料容器の開発および試験を実施した。ポリイミドチューブを用いた試料容器では 容器自体からBragg反射が生じないため、X線回折用の試料容器として適している。この容器を用いて典型的な水素吸蔵合金の一つであるLaNi4.5Al0.5 は水素化に成功したが、V系BCC合金では水素化が進行しなかった。ポリイミドチューブと同程度の内径のアルミニウム製チューブを用いた容器ではV系BCC合金でも水素化による回折パターンの変化が観測されたため、ポリイミドチューブに問題がある可能性がある。水素貯蔵合金に対する水素化反応過程その場Ⅹ線回折測定にポリイミドチューブを試料容器に用いるには改良が必要である。 | |||||
書誌情報 |
SPring-8/SACLA利用研究成果集 巻 6, 号 2, p. 185-189, 発行日 2018-08 |
|||||
出版者 | ||||||
出版者 | 公益財団法人 高輝度光科学研究センター | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2187-6886 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.18957/rr.6.2.185 |