量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Abstract
Background: We conducted a retrospective multicenter study to assess the clinical outcomes of carbon‐ion radiotherapy (CIRT) for head and neck malignancies (Japan Carbon‐Ion Radiation Oncology Study Group [J‐CROS] study: 1402 HN). We aimed to evaluate the safety and efficacy of CIRT in patients with external auditory canal (EAC) and middle ear (ME) carcinomas.
Methods: Thirty‐one patients treated with CIRT at four Japanese institutions were analyzed. Fourteen patients (45.2%) had squamous cell carcinomas, 13 (41.9%) had adenoid cystic carcinomas, and four (12.9%) had other types. Nineteen (61.3%), six (19.4%), three (9.7%), and three (9.7%) patients had T4, T3, T2, and T1 disease, respectively. All patients had N0M0 status. The median radiation dose was 64 Gy (relative biological effectiveness) in 16 fractions. The median gross tumor volume was 33.3 mL.
Results: The median follow‐up period was 18.4 months (range, 5.1‐85.6). The
1‐and 3‐year local control and overall survival rates were 75.0% and 55.0% and 79.3% and 58.7%, respectively. Regarding grade 3 or higher toxicities, three patients (9.7%) had grade 3 dermatitis, one (3.2%) had grade 3 mucositis, and two (6.5%) had grade 3 central nervous necrosis (ie, radiation‐induced brain necrosis). No grade 4 or worse reactions were observed.
Conclusion: CIRT was effective for EAC and ME carcinomas.