WEKO3
アイテム
{"_buckets": {"deposit": "7762ce48-d7c0-40e2-80e1-e2c9d831204b"}, "_deposit": {"created_by": 1, "id": "49312", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "49312"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00049312", "sets": ["1"]}, "author_link": ["497683", "497684", "497678", "497680", "497679", "497682", "497681"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "080015-3", "bibliographicPageStart": "080015-1", "bibliographicVolumeNumber": "2011", "bibliographic_titles": [{"bibliographic_title": "AIP Conference Proceedings"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A prototype penning ionization gauge ion source has been developed for the installation of a 1-MeV compact ion microbeam system. The ion source must generate an ion beam with high brightness and low energy while consuming a minimum of low electric power consumption and fitting within a small size. A prototype penning ionization gage (PIG) ion source with two electromagnets, which generates an ion beam from high-density plasma in a small volume passing through a cathode with a small through-hole, was designed and constructed. The prototype PIG ion source generated low-energy hydrogen ion beams with the almost same distribution of ion species as a typical PIG ion source in the preliminary tests. The brightnesses of the ion beam with all ion species and proton beam were calculated and estimated to be 80 A/(m2SrV) and 8 A/(m2SrV) using the experimentally measured beam current and on the basis of the ion distribution, respectively. These values are sufficient for the installation in a compact ion microbeam system.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "96519", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.5053370", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石井, 保行"}], "nameIdentifiers": [{"nameIdentifier": "497678", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大久保, 猛"}], "nameIdentifiers": [{"nameIdentifier": "497679", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柏木, 啓次"}], "nameIdentifiers": [{"nameIdentifier": "497680", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三宅, 善信"}], "nameIdentifiers": [{"nameIdentifier": "497681", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井 保行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "497682", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大久保 猛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "497683", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柏木 啓次", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "497684", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/49312", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-12-13"}, "publish_date": "2018-12-13", "publish_status": "0", "recid": "49312", "relation": {}, "relation_version_is_last": true, "title": ["Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system"], "weko_shared_id": -1}
Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system
https://repo.qst.go.jp/records/49312
https://repo.qst.go.jp/records/4931299958c53-8f98-46e2-8a3f-b0bb0bc54340
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-12-13 | |||||
タイトル | ||||||
タイトル | Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
石井, 保行
× 石井, 保行× 大久保, 猛× 柏木, 啓次× 三宅, 善信× 石井 保行× 大久保 猛× 柏木 啓次 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A prototype penning ionization gauge ion source has been developed for the installation of a 1-MeV compact ion microbeam system. The ion source must generate an ion beam with high brightness and low energy while consuming a minimum of low electric power consumption and fitting within a small size. A prototype penning ionization gage (PIG) ion source with two electromagnets, which generates an ion beam from high-density plasma in a small volume passing through a cathode with a small through-hole, was designed and constructed. The prototype PIG ion source generated low-energy hydrogen ion beams with the almost same distribution of ion species as a typical PIG ion source in the preliminary tests. The brightnesses of the ion beam with all ion species and proton beam were calculated and estimated to be 80 A/(m2SrV) and 8 A/(m2SrV) using the experimentally measured beam current and on the basis of the ion distribution, respectively. These values are sufficient for the installation in a compact ion microbeam system. | |||||
書誌情報 |
AIP Conference Proceedings 巻 2011, p. 080015-1-080015-3, 発行日 2018-10 |
|||||
出版者 | ||||||
出版者 | AIP | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 96519 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.5053370 |