WEKO3
アイテム
{"_buckets": {"deposit": "7d1de9b8-f95d-41c7-9b33-93f14bc60ca8"}, "_deposit": {"created_by": 1, "id": "49067", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "49067"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00049067", "sets": ["1"]}, "author_link": ["757928", "757929", "757925", "757924", "757927", "757926"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "247", "bibliographicPageStart": "242", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "Radiological Physics and Technology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A treatment of carbon-ion radiotherapy (CIRT) is generally evaluated using the dose weighted by relative biological effectiveness (RBE) while ignoring the radiation quality varying in the patient. In this study, we have developed a method of estimating linear energy transfer (LET) from the RBE in an archived treatment plan to represent the radiation quality of the treatment. The LET in a beam database was associated with the RBE by two fitting functions per energy, one for the spread-out Bragg peak (SOBP) and the other for shallower depths, to be differentiated by RBE per energy per modulation. The estimated LET was generally consistent with the original calculation within a few keV/μm, except for the overkill region near the distal end of SOBP. The knowledge of experimental radiobiology can thereby be associated with CIRT treatments through LET, which will potentially contribute to deeper understanding of clinical radiobiology and further optimization of CIRT.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Singapore"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "29470773", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s12194-018-0444-7", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1007/s12194-018-0444-7", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1865-0333", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "757924", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsufuji, Naruhiro"}], "nameIdentifiers": [{"nameIdentifier": "757925", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "757926", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "757927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsufuji, Naruhiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "757928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "757929", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/49067", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-02-26"}, "publish_date": "2018-02-26", "publish_status": "0", "recid": "49067", "relation": {}, "relation_version_is_last": true, "title": ["Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan"], "weko_shared_id": -1}
Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan
https://repo.qst.go.jp/records/49067
https://repo.qst.go.jp/records/490679d339d6a-e05f-4320-8285-ff05dfe41821
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-02-26 | |||||
タイトル | ||||||
タイトル | Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kanematsu, Nobuyuki
× Kanematsu, Nobuyuki× Matsufuji, Naruhiro× Inaniwa, Taku× Kanematsu, Nobuyuki× Matsufuji, Naruhiro× Inaniwa, Taku |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A treatment of carbon-ion radiotherapy (CIRT) is generally evaluated using the dose weighted by relative biological effectiveness (RBE) while ignoring the radiation quality varying in the patient. In this study, we have developed a method of estimating linear energy transfer (LET) from the RBE in an archived treatment plan to represent the radiation quality of the treatment. The LET in a beam database was associated with the RBE by two fitting functions per energy, one for the spread-out Bragg peak (SOBP) and the other for shallower depths, to be differentiated by RBE per energy per modulation. The estimated LET was generally consistent with the original calculation within a few keV/μm, except for the overkill region near the distal end of SOBP. The knowledge of experimental radiobiology can thereby be associated with CIRT treatments through LET, which will potentially contribute to deeper understanding of clinical radiobiology and further optimization of CIRT. | |||||
書誌情報 |
Radiological Physics and Technology 巻 11, 号 2, p. 242-247, 発行日 2018-02 |
|||||
出版者 | ||||||
出版者 | Springer Singapore | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1865-0333 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 29470773 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12194-018-0444-7 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1007/s12194-018-0444-7 |