WEKO3
アイテム
{"_buckets": {"deposit": "394288ac-a303-445e-b907-59ecc441783e"}, "_deposit": {"created_by": 1, "id": "48459", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48459"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048459", "sets": ["1"]}, "author_link": ["487212", "487213", "487217", "487218", "487214", "487216", "487211", "487209", "487215", "487210"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "206", "bibliographicPageStart": "202", "bibliographicVolumeNumber": "404", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "高レベル放射性廃液(HLW)の放射能毒性を短期間で減少させることを目的に、抽出クロマトグラフィーを用いたHLWからのマイナーアクチノイド(MA)及びランタノイド回収を目指している。CMPO (octyl(phenyl)-N,N-diisobutylcarbonoylmethylpho sphine oxide)-HDEHP (bis(2-ethylhexyl)hydrogen phosphate)を多孔質シリカに含浸させた吸着材を試作し、この特性をMAとランタノイドの吸着実験と硝酸アンモニウムを用いた溶離実験により評価した。その結果、MAとランタノイドの吸着には成功したが、溶離ではランタノイドの残留が確認された。この理由を調べるため、粒子励起X線放出トモグラフィで残留するランタノイドの分布を測定したところ、吸着材の中心部分の濃度が高(残留が多いことが分)かった。このことから、溶離率の向上には、多孔質シリカの細孔径を拡大するなど溶離剤が中心部分まで容易に浸透するような改良が必要であることが示唆された。", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.nimb.2017.01.055", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.sciencedirect.com/science/article/pii/S0168583X17300708"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.sciencedirect.com/science/article/pii/S0168583X17300708", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-583X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sou, Watanabe"}], "nameIdentifiers": [{"nameIdentifier": "487209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sano, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "487210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shiwaku, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "487211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yaita, Tsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "487212", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohno, Simpei"}], "nameIdentifiers": [{"nameIdentifier": "487213", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Arai, Tsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "487214", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuura, Haruaki"}], "nameIdentifiers": [{"nameIdentifier": "487215", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koka, Masahi"}], "nameIdentifiers": [{"nameIdentifier": "487216", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satoh, Takahiro"}], "nameIdentifiers": [{"nameIdentifier": "487217", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 隆博", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "487218", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Local structure and distribution of remaining elements inside extraction chromatography adsorbents", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Local structure and distribution of remaining elements inside extraction chromatography adsorbents"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48459", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-02-06"}, "publish_date": "2018-02-06", "publish_status": "0", "recid": "48459", "relation": {}, "relation_version_is_last": true, "title": ["Local structure and distribution of remaining elements inside extraction chromatography adsorbents"], "weko_shared_id": -1}
Local structure and distribution of remaining elements inside extraction chromatography adsorbents
https://repo.qst.go.jp/records/48459
https://repo.qst.go.jp/records/48459b8cdcc81-8dd0-4db4-907d-406e76988dcc
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-02-06 | |||||
タイトル | ||||||
タイトル | Local structure and distribution of remaining elements inside extraction chromatography adsorbents | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sou, Watanabe
× Sou, Watanabe× Sano, Yuichi× Shiwaku, Hideaki× Yaita, Tsuyoshi× Ohno, Simpei× Arai, Tsuyoshi× Matsuura, Haruaki× Koka, Masahi× Satoh, Takahiro× 佐藤 隆博 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 高レベル放射性廃液(HLW)の放射能毒性を短期間で減少させることを目的に、抽出クロマトグラフィーを用いたHLWからのマイナーアクチノイド(MA)及びランタノイド回収を目指している。CMPO (octyl(phenyl)-N,N-diisobutylcarbonoylmethylpho sphine oxide)-HDEHP (bis(2-ethylhexyl)hydrogen phosphate)を多孔質シリカに含浸させた吸着材を試作し、この特性をMAとランタノイドの吸着実験と硝酸アンモニウムを用いた溶離実験により評価した。その結果、MAとランタノイドの吸着には成功したが、溶離ではランタノイドの残留が確認された。この理由を調べるため、粒子励起X線放出トモグラフィで残留するランタノイドの分布を測定したところ、吸着材の中心部分の濃度が高(残留が多いことが分)かった。このことから、溶離率の向上には、多孔質シリカの細孔径を拡大するなど溶離剤が中心部分まで容易に浸透するような改良が必要であることが示唆された。 | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 巻 404, p. 202-206, 発行日 2017-06 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nimb.2017.01.055 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.sciencedirect.com/science/article/pii/S0168583X17300708 | |||||
関連名称 | http://www.sciencedirect.com/science/article/pii/S0168583X17300708 |