{"_buckets": {"deposit": "dc8bda9c-5cfa-4525-9cc5-23772608c26e"}, "_deposit": {"created_by": 1, "id": "47995", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47995"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047995", "sets": ["1"]}, "author_link": ["481815", "481822", "481823", "481818", "481820", "481819", "481821", "481817", "481816"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "063307-5", "bibliographicPageStart": "063307-1", "bibliographicVolumeNumber": "87", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We propose a simple and effective synchronization technique between a reference electrical oscillator and a mode-locked laser for a narrowband picosecond Laser-Compton scattering Gamma-ray source by using a commercial-based 1-chip frequency synthesizer, which is widely used in radio communication. The mode-locked laser has been successfully synchronized in time with a jitter of 180 fs RMS for 10 Hz - 100 kHz bandwidth. A good stability of 640 uHz at 80 MHz repetition rate for 10 hours operation has also been confirmed. We discuss in detail the design and performance of this technique (in terms of timing jitter, stability, and validity).", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.4954733", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://scitation.aip.org/content/aip/journal/rsi/87/6/10.1063/1.4954733"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://scitation.aip.org/content/aip/journal/rsi/87/6/10.1063/1.4954733", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Michiaki"}], "nameIdentifiers": [{"nameIdentifier": "481815", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kosuge, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "481816", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kiriyama, Hiromitsu"}], "nameIdentifiers": [{"nameIdentifier": "481817", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hajima, Ryoichi"}], "nameIdentifiers": [{"nameIdentifier": "481818", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kondo, Kiminori"}], "nameIdentifiers": [{"nameIdentifier": "481819", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 道昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481820", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "桐山 博光", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481821", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "羽島 良一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481822", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "近藤 公伯", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "481823", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Simple synchronization technique of a mode-locked laser for Laser-Compton scattering Gamma-ray source", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Simple synchronization technique of a mode-locked laser for Laser-Compton scattering Gamma-ray source"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47995", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-06-05"}, "publish_date": "2017-06-05", "publish_status": "0", "recid": "47995", "relation": {}, "relation_version_is_last": true, "title": ["Simple synchronization technique of a mode-locked laser for Laser-Compton scattering Gamma-ray source"], "weko_shared_id": -1}
Simple synchronization technique of a mode-locked laser for Laser-Compton scattering Gamma-ray source
https://repo.qst.go.jp/records/47995
https://repo.qst.go.jp/records/47995a7fa8d0a-9617-4e82-9fee-4330a241b29c
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-05 | |||||
タイトル | ||||||
タイトル | Simple synchronization technique of a mode-locked laser for Laser-Compton scattering Gamma-ray source | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Michiaki
× Mori, Michiaki× Kosuge, Atsushi× Kiriyama, Hiromitsu× Hajima, Ryoichi× Kondo, Kiminori× 森 道昭× 桐山 博光× 羽島 良一× 近藤 公伯 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We propose a simple and effective synchronization technique between a reference electrical oscillator and a mode-locked laser for a narrowband picosecond Laser-Compton scattering Gamma-ray source by using a commercial-based 1-chip frequency synthesizer, which is widely used in radio communication. The mode-locked laser has been successfully synchronized in time with a jitter of 180 fs RMS for 10 Hz - 100 kHz bandwidth. A good stability of 640 uHz at 80 MHz repetition rate for 10 hours operation has also been confirmed. We discuss in detail the design and performance of this technique (in terms of timing jitter, stability, and validity). | |||||
書誌情報 |
Review of Scientific Instruments 巻 87, 号 6, p. 063307-1-063307-5, 発行日 2016-06 |
|||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.4954733 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://scitation.aip.org/content/aip/journal/rsi/87/6/10.1063/1.4954733 | |||||
関連名称 | http://scitation.aip.org/content/aip/journal/rsi/87/6/10.1063/1.4954733 |