WEKO3
アイテム
{"_buckets": {"deposit": "fa11e7b0-a7f9-4913-a05f-dfa256a621c3"}, "_deposit": {"created_by": 1, "id": "47812", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47812"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047812", "sets": ["1"]}, "author_link": ["479950", "479948", "479951", "479954", "479953", "479956", "479952", "479949", "479955"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1062", "bibliographicPageEnd": "20150988-8", "bibliographicPageStart": "20150988-1", "bibliographicVolumeNumber": "89", "bibliographic_titles": [{"bibliographic_title": "The British journal of radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "One approach to improving image quality of CT is to use metal artefact reduction image processing, such as single-energy metal artefact reduction (SEMAR). To quantify the impact of image correction on the quality of carbon-ion dose distribution, treatment planning using SEMAR was evaluated.", "subitem_description_type": "Abstract"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "26942839", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1259/bjr.20150988", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0007-1285", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Miki, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "479948", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "479949", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, Azusa"}], "nameIdentifiers": [{"nameIdentifier": "479950", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Naganawa, Kensuke"}], "nameIdentifiers": [{"nameIdentifier": "479951", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koto, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "479952", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479953", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷川 安都佐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479954", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長縄 憲亮", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479955", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小藤 昌志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479956", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47812", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-04-26"}, "publish_date": "2017-04-26", "publish_status": "0", "recid": "47812", "relation": {}, "relation_version_is_last": true, "title": ["Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning."], "weko_shared_id": -1}
Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning.
https://repo.qst.go.jp/records/47812
https://repo.qst.go.jp/records/47812e08a0907-43fc-4da6-8144-b8e41969c346
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-04-26 | |||||
タイトル | ||||||
タイトル | Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Miki, Kentaro
× Miki, Kentaro× Mori, Shinichiro× Hasegawa, Azusa× Naganawa, Kensuke× Koto, Masashi× 森 慎一郎× 長谷川 安都佐× 長縄 憲亮× 小藤 昌志 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | One approach to improving image quality of CT is to use metal artefact reduction image processing, such as single-energy metal artefact reduction (SEMAR). To quantify the impact of image correction on the quality of carbon-ion dose distribution, treatment planning using SEMAR was evaluated. | |||||
書誌情報 |
The British journal of radiology 巻 89, 号 1062, p. 20150988-1-20150988-8, 発行日 2016-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0007-1285 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 26942839 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1259/bjr.20150988 |