WEKO3
アイテム
{"_buckets": {"deposit": "e514250e-aedb-4a9a-b27c-277d9a7370c6"}, "_deposit": {"created_by": 1, "id": "47606", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47606"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047606", "sets": ["1"]}, "author_link": ["477186", "477191", "477187", "477190", "477189", "477188", "477192"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "224", "bibliographicPageStart": "220", "bibliographicVolumeNumber": "107", "bibliographic_titles": [{"bibliographic_title": "Applied Radiation and Isotopes"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Radon and thoron as well as their short-lived progenies are decay products of the radium and thorium series decays. They are the most important radionuclide elements with respect to public exposure. To utilize the semiconductor pixel radiation Timepix chip for the measurement of active and real-time alpha particles from radon, thoron and their progenies, it is necessary to check the registration and visualization of the chip.\nAn energy check for radon, thoron and their progenies, as well as for 241Am and210Po sources, was performed using the radon and thoron chambers at NIRS (National Institute of Radiological Sciences). The check found an energy resolution of 200 keV with a 14% efficiency as well as a linear dependency between the channel number (cluster volume) and the energy. The coefficient of determination r2 of 0.99 for the range of 5 to 9 MeV was calculated. In addition, an offset for specific Timepix configurations between pre-calibration for low energy from 6 to 60 keV, and the actual calibration for alpha particles with energies from 4000 to 9000 keV, was detected.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.apradiso.2015.10.023", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0969-8043", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ミロソラフ, ヤニック"}], "nameIdentifiers": [{"nameIdentifier": "477186", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ploc, Ondrej"}], "nameIdentifiers": [{"nameIdentifier": "477187", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Michael, Fiederle"}], "nameIdentifiers": [{"nameIdentifier": "477188", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Procz, Simon"}], "nameIdentifiers": [{"nameIdentifier": "477189", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kavasi, Norbert"}], "nameIdentifiers": [{"nameIdentifier": "477190", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ミロソラフ ヤニック", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "477191", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kavasi Norbert", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "477192", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Optimization of the Timepix chip to measurement of radon, thoron and their progenies", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of the Timepix chip to measurement of radon, thoron and their progenies"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47606", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-01-06"}, "publish_date": "2017-01-06", "publish_status": "0", "recid": "47606", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of the Timepix chip to measurement of radon, thoron and their progenies"], "weko_shared_id": -1}
Optimization of the Timepix chip to measurement of radon, thoron and their progenies
https://repo.qst.go.jp/records/47606
https://repo.qst.go.jp/records/47606fd3b33f5-29a0-47df-b6f2-f3b301f46b66
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-01-06 | |||||
タイトル | ||||||
タイトル | Optimization of the Timepix chip to measurement of radon, thoron and their progenies | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
ミロソラフ, ヤニック
× ミロソラフ, ヤニック× Ploc, Ondrej× Michael, Fiederle× Procz, Simon× Kavasi, Norbert× ミロソラフ ヤニック× Kavasi Norbert |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Radon and thoron as well as their short-lived progenies are decay products of the radium and thorium series decays. They are the most important radionuclide elements with respect to public exposure. To utilize the semiconductor pixel radiation Timepix chip for the measurement of active and real-time alpha particles from radon, thoron and their progenies, it is necessary to check the registration and visualization of the chip. An energy check for radon, thoron and their progenies, as well as for 241Am and210Po sources, was performed using the radon and thoron chambers at NIRS (National Institute of Radiological Sciences). The check found an energy resolution of 200 keV with a 14% efficiency as well as a linear dependency between the channel number (cluster volume) and the energy. The coefficient of determination r2 of 0.99 for the range of 5 to 9 MeV was calculated. In addition, an offset for specific Timepix configurations between pre-calibration for low energy from 6 to 60 keV, and the actual calibration for alpha particles with energies from 4000 to 9000 keV, was detected. |
|||||
書誌情報 |
Applied Radiation and Isotopes 巻 107, p. 220-224, 発行日 2016-01 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0969-8043 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.apradiso.2015.10.023 |