WEKO3
アイテム
{"_buckets": {"deposit": "44ef1d35-9a58-4872-8788-1fb5b998f83a"}, "_deposit": {"created_by": 1, "id": "47405", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47405"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047405", "sets": ["1"]}, "author_link": ["474652", "474650", "474656", "474653", "474655", "474651", "474654", "474649", "474648"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "266", "bibliographicPageStart": "259", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "International Journal of Bioautomation"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Abstract: Electroporation-based cancer treatment techniques are currently after active investigations in the field of drug delivery, optimization of electrical parameters and elucidation of the exact mechanisms at a molecular level. The present study is designed to investigate the exact in vivo redistribution and persistence of nanoparticles in the tumor tissue\n f colon-cancer grafted mice after electroporation with two different kinds of electrodes.The aim of the study is to avoid artifacts during electroporation due to accumulation of nanoparticles in the surrounding non-cancer tissues. The isolated electrodes are appropriate for the treatment of 3-dimensional tumors and have a large potential in this field. Keywords: Electroassisted drug delivery, in vivo imaging, Cancer, Nanoparticles, Quantum dots.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Bulgarian Academy of Sciences"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1314-1902", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nikolova, Biliana"}], "nameIdentifiers": [{"nameIdentifier": "474648", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Atanasova, Severina"}], "nameIdentifiers": [{"nameIdentifier": "474649", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mudrov, Tsvetan"}], "nameIdentifiers": [{"nameIdentifier": "474650", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsoneva, Iana"}], "nameIdentifiers": [{"nameIdentifier": "474651", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhelev, Zhivko"}], "nameIdentifiers": [{"nameIdentifier": "474652", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Bakalova, Rumiana"}], "nameIdentifiers": [{"nameIdentifier": "474653", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoki, Ichio"}], "nameIdentifiers": [{"nameIdentifier": "474654", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "バカロバ ルミアナ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474655", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青木 伊知男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474656", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Image-guided Electro-assisted Drug Delivery: Comparison between Two Types of Electrodes", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Image-guided Electro-assisted Drug Delivery: Comparison between Two Types of Electrodes"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47405", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-05-18"}, "publish_date": "2016-05-18", "publish_status": "0", "recid": "47405", "relation": {}, "relation_version_is_last": true, "title": ["Image-guided Electro-assisted Drug Delivery: Comparison between Two Types of Electrodes"], "weko_shared_id": -1}
Image-guided Electro-assisted Drug Delivery: Comparison between Two Types of Electrodes
https://repo.qst.go.jp/records/47405
https://repo.qst.go.jp/records/47405f8e66b82-9d8a-4c20-9c29-40f40be3d9ab
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-05-18 | |||||
タイトル | ||||||
タイトル | Image-guided Electro-assisted Drug Delivery: Comparison between Two Types of Electrodes | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nikolova, Biliana
× Nikolova, Biliana× Atanasova, Severina× Mudrov, Tsvetan× Tsoneva, Iana× Zhelev, Zhivko× Bakalova, Rumiana× Aoki, Ichio× バカロバ ルミアナ× 青木 伊知男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Abstract: Electroporation-based cancer treatment techniques are currently after active investigations in the field of drug delivery, optimization of electrical parameters and elucidation of the exact mechanisms at a molecular level. The present study is designed to investigate the exact in vivo redistribution and persistence of nanoparticles in the tumor tissue f colon-cancer grafted mice after electroporation with two different kinds of electrodes.The aim of the study is to avoid artifacts during electroporation due to accumulation of nanoparticles in the surrounding non-cancer tissues. The isolated electrodes are appropriate for the treatment of 3-dimensional tumors and have a large potential in this field. Keywords: Electroassisted drug delivery, in vivo imaging, Cancer, Nanoparticles, Quantum dots. |
|||||
書誌情報 |
International Journal of Bioautomation 巻 19, 号 2, p. 259-266, 発行日 2015-08 |
|||||
出版者 | ||||||
出版者 | Bulgarian Academy of Sciences | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1314-1902 |