{"_buckets": {"deposit": "2387b527-1912-452f-bbfe-dde2bef08a62"}, "_deposit": {"created_by": 1, "id": "47397", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47397"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047397", "sets": ["1"]}, "author_link": ["474522", "474533", "474521", "474529", "474530", "474523", "474526", "474525", "474531", "474524", "474532", "474528", "474527"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "283", "bibliographicPageStart": "279", "bibliographicVolumeNumber": "115", "bibliographic_titles": [{"bibliographic_title": "Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Carbon-ion radiotherapy uses spread-out Bragg peaks (SOBP) to produce uniform biological effects within a target volume. The relative biological effectiveness is determined by the in vitro cell kill after a single dose is employed to design the SOBP. A question remains as to whether biological effects for in vivo tissues after fractionated doses are also uniform within the SOBP.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier Scientific Publishers"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "25981129", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.radonc.2015.04.007", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0167-8140", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Uzawa, Akiko"}], "nameIdentifiers": [{"nameIdentifier": "474521", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ando, Koichi"}], "nameIdentifiers": [{"nameIdentifier": "474522", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kase, Yuki"}], "nameIdentifiers": [{"nameIdentifier": "474523", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirayama, Ryoichi"}], "nameIdentifiers": [{"nameIdentifier": "474524", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Yoshitaka"}], "nameIdentifiers": [{"nameIdentifier": "474525", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsufuji, Naruhiro"}], "nameIdentifiers": [{"nameIdentifier": "474526", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koike, Sachiko"}], "nameIdentifiers": [{"nameIdentifier": "474527", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kobashi, Gen"}], "nameIdentifiers": [{"nameIdentifier": "474528", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鵜澤 玲子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474529", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平山 亮一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474530", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松藤 成弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474531", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小池 幸子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474532", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小橋 元", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474533", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Designing a ridge filter based on a mouse foot skin reaction to spread out Bragg-peaks for carbon-ion radiotherapy.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Designing a ridge filter based on a mouse foot skin reaction to spread out Bragg-peaks for carbon-ion radiotherapy."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47397", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-05-18"}, "publish_date": "2016-05-18", "publish_status": "0", "recid": "47397", "relation": {}, "relation_version_is_last": true, "title": ["Designing a ridge filter based on a mouse foot skin reaction to spread out Bragg-peaks for carbon-ion radiotherapy."], "weko_shared_id": -1}
Designing a ridge filter based on a mouse foot skin reaction to spread out Bragg-peaks for carbon-ion radiotherapy.
https://repo.qst.go.jp/records/47397
https://repo.qst.go.jp/records/47397fa92c483-67df-4ad9-992b-7304a9992c15
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-05-18 | |||||
タイトル | ||||||
タイトル | Designing a ridge filter based on a mouse foot skin reaction to spread out Bragg-peaks for carbon-ion radiotherapy. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Uzawa, Akiko
× Uzawa, Akiko× Ando, Koichi× Kase, Yuki× Hirayama, Ryoichi× Matsumoto, Yoshitaka× Matsufuji, Naruhiro× Koike, Sachiko× Kobashi, Gen× 鵜澤 玲子× 平山 亮一× 松藤 成弘× 小池 幸子× 小橋 元 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Carbon-ion radiotherapy uses spread-out Bragg peaks (SOBP) to produce uniform biological effects within a target volume. The relative biological effectiveness is determined by the in vitro cell kill after a single dose is employed to design the SOBP. A question remains as to whether biological effects for in vivo tissues after fractionated doses are also uniform within the SOBP. | |||||
書誌情報 |
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 巻 115, 号 2, p. 279-283, 発行日 2015-05 |
|||||
出版者 | ||||||
出版者 | Elsevier Scientific Publishers | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0167-8140 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25981129 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radonc.2015.04.007 |