{"_buckets": {"deposit": "25dda111-2787-47dc-85fc-2cf9dc39b532"}, "_deposit": {"created_by": 1, "id": "47235", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47235"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047235", "sets": ["1"]}, "author_link": ["472350", "472351", "472356", "472358", "472359", "472360", "472361", "472352", "472354", "472348", "472355", "472357", "472349", "472353"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "126107-3", "bibliographicPageStart": "126107-1", "bibliographicVolumeNumber": "85", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The light intensity of 6Li III line spectrum at λ = 516.7 nm was observed during 6Li3+ beam tuning at the Hyper-Electron Cyclotron Resonance (ECR) ion source. Separation of ion species of the same charge to mass ratio with an electromagnetic mass analyzer is known to be an exceptionally complex process. However, 6Li III line intensity observation conducted in this study gives new insights into its simplification of this process. The light intensity of 6Li III line spectrum from the ECR plasma was found to have a strong correlation with the extracted 6Li3+ beam intensity from the RIKEN Azimuthal\nVarying Field cyclotron.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.4904341", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Muto, Hideshi"}], "nameIdentifiers": [{"nameIdentifier": "472348", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohshiro, Yukimitsu"}], "nameIdentifiers": [{"nameIdentifier": "472349", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaka, Shoichi"}], "nameIdentifiers": [{"nameIdentifier": "472350", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Shin-ichi"}], "nameIdentifiers": [{"nameIdentifier": "472351", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Oyaizu, Michihiro"}], "nameIdentifiers": [{"nameIdentifier": "472352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaguchi, Hidetoshi"}], "nameIdentifiers": [{"nameIdentifier": "472353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kobayashi, Kiyoshi"}], "nameIdentifiers": [{"nameIdentifier": "472354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kotaka, Yasuteru"}], "nameIdentifiers": [{"nameIdentifier": "472355", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishimura, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "472356", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kubono, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "472357", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kase, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "472358", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hattori, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "472359", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimoura, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "472360", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "服部 俊幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "472361", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "6Li III light intensity observation for 6Li3+ ion beam operation at Hyper-Electron Cyclotron Resonance ion source", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "6Li III light intensity observation for 6Li3+ ion beam operation at Hyper-Electron Cyclotron Resonance ion source"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47235", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-08-07"}, "publish_date": "2015-08-07", "publish_status": "0", "recid": "47235", "relation": {}, "relation_version_is_last": true, "title": ["6Li III light intensity observation for 6Li3+ ion beam operation at Hyper-Electron Cyclotron Resonance ion source"], "weko_shared_id": -1}
6Li III light intensity observation for 6Li3+ ion beam operation at Hyper-Electron Cyclotron Resonance ion source
https://repo.qst.go.jp/records/47235
https://repo.qst.go.jp/records/472350ae89626-8d4c-4c67-abba-9fdb8f37169f
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-08-07 | |||||
タイトル | ||||||
タイトル | 6Li III light intensity observation for 6Li3+ ion beam operation at Hyper-Electron Cyclotron Resonance ion source | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Muto, Hideshi
× Muto, Hideshi× Ohshiro, Yukimitsu× Yamaka, Shoichi× Watanabe, Shin-ichi× Oyaizu, Michihiro× Yamaguchi, Hidetoshi× Kobayashi, Kiyoshi× Kotaka, Yasuteru× Nishimura, Makoto× Kubono, Shigeru× Kase, Masayuki× Hattori, Toshiyuki× Shimoura, Susumu× 服部 俊幸 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The light intensity of 6Li III line spectrum at λ = 516.7 nm was observed during 6Li3+ beam tuning at the Hyper-Electron Cyclotron Resonance (ECR) ion source. Separation of ion species of the same charge to mass ratio with an electromagnetic mass analyzer is known to be an exceptionally complex process. However, 6Li III line intensity observation conducted in this study gives new insights into its simplification of this process. The light intensity of 6Li III line spectrum from the ECR plasma was found to have a strong correlation with the extracted 6Li3+ beam intensity from the RIKEN Azimuthal Varying Field cyclotron. |
|||||
書誌情報 |
Review of Scientific Instruments 巻 85, 号 12, p. 126107-1-126107-3, 発行日 2014-12 |
|||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.4904341 |