量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
In radiation therapy, it is necessary to preset a monitor unit in an irradiation control system to deliver a prescribed absolute dose to a reference point in the planning target volume. The purpose of this study was to develop a model-based monitor unit calculation method for proton-beam therapy with a single-ring wobbling system. The absorbed dose at a calibration point per monitor unit had been measured for each beam-specific measurement condition without a patient-specific collimator or range compensator before proton therapeutic irradiation at Shizuoka Cancer Center. In this paper, we propose a simplified dose output model to obtain the output ratio between a beam-specific dose and a reference field dose, from which a monitor unit for the proton treatment could be derived without beam-specific measurements. The model parameters were determined to fit some typical data measured in a proton treatment room, called a Gantry 1 course. Then, the model calculation was compared with 5456 dose output ratios that had been measured for 150-, 190- and 220 MeV therapeutic proton beams in two treatment rooms over the past decade. The mean value and standard deviation of the difference between the measurement and the model calculation were respectively 0.00% and 0.27% for the Gantry 1 course, and -0.25% and 0.35% for the Gantry 2 course. The model calculation was in good agreement with the measured beam-specific doses, within 1%, except for conditions less frequently used for treatment. The small variation for the various beam conditions shows the high long-term reproducibility of the measurement and high degree of compatibility of the two treatment rooms. Therefore, the model was expected to assure the setting value of the dose monitor for treatment, to save the effort required for beam-specific measurement, and to predict the dose output for new beam conditions in the future.