量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Additional value of FDG-PET to contrast enhanced-computed tomography (CT) for the diagnosis of mediastinal lymph node metastasis in non-small cell lung cancer: a Japanese multicenter clinical study.
利用統計を見る
Objective
This study was a controlled multicenter clinical study to verify the diagnostic effects of additional FDG-PET to contrast-enhanced CT for mediastinal lymph node metastasis in patients with operable non-small cell lung cancer (NSCLC).
Methods
NSCLC patients with enlarged mediastinal lymph nodes (short diameter, 7–20 mm), confirmed using contrast-enhanced CT, were examined using FDG-PET to detect metastases prior to surgery. The primary endpoint was the accuracy for concomitantly used CT and FDG-PET showing the additional effects of FDG, compared with CT alone. The secondary endpoints were the clinical impact of FDG-PET on therapeutic decisions and adverse reaction from FDG administration. The images were interpreted by investigators at each institution. Moreover, blinded readings were performed by an image interpretation committee independent of the institutions. The gold standard was the pathological diagnosis determined by surgery or biopsy after PET, and patients in whom a pathological diagnosis was not obtained were excluded from the analysis.
Results
Among 99 subjects, the results for 81 subjects eligible for analysis showed that the accuracy improved from 69.1% (56/81) for CT alone to 75.3% (61/81) for CT + PET (p = 0.404). These findings contributed to treatment decisions in 63.0% (51/81) of the cases, mainly with regard to the selection of the operative procedure. The results of the image interpretation committee showed that the accuracy improved from 64.2% (52/81) (95% CI 52.8–74.6) for CT to 75.3% (61/81) (95% CI 64.5–84.2) for CT + PET. The accuracy for 106 mediastinal lymph nodes improved significantly from 62.3% (66/106) (95% CI 52.3–71.5) for CT to 79.2% (84/106) (95% CI 70.3–86.5) for CT + PET (p < 0.05). We found that no serious adverse drug reactions appeared in any of the 99 patients who received FDG, except for transient mild outliers in the laboratory data for two patients.