{"_buckets": {"deposit": "aa98a397-77a5-471a-b21d-f4ecf0a9a3c0"}, "_deposit": {"created_by": 1, "id": "46254", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46254"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046254", "sets": ["1"]}, "author_link": ["460631", "460621", "460629", "460630", "460627", "460624", "460634", "460622", "460632", "460633", "460619", "460623", "460628", "460620", "460625", "460626"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "41", "bibliographicPageStart": "36", "bibliographicVolumeNumber": "274", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments \u0026 Methods in Physics Research Section B"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We verified that the two-step etching method of the combination of pre-etching with PEW (Potassium hydroxide + Ethanol + Water) solution and post-etching with NaOH solution makes drastic improvement of charge resolution for high Z/b particles (Z: nuclear charge, b: velocity) in CR-39 nuclear track detectors. Detectors were exposed to several heavy ions from Ne to Kr with the energies of \u003c500 MeV/n at HIMAC\n(Heavy Ion Medical Accelerator in Chiba). The optimum etching conditions were determined to be a preetching of PEW solution with concentration of 60 wt% of ethanol for 40 min and a post-etching of 7N NaOH for 12 h. This resulted in a charge resolution for Kr (Z/b~60) of 0.18 c.u. (charge units). The Z/b detection threshold was increased as a function of ethanol concentration in PEW pre-etching solutions. We found that the two-step etching method would be useful technique for the precise charge identification by a single track measurement. The 60 wt% ethanol concentration in PEW would be adequate selection for the purpose of trans-iron nuclei measurement discriminating abundant light nuclei in galactic cosmic rays.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-583X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kodaira, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "460619", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Naka, Shuichiro"}], "nameIdentifiers": [{"nameIdentifier": "460620", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Nakahiro"}], "nameIdentifiers": [{"nameIdentifier": "460621", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawashima, Hajime"}], "nameIdentifiers": [{"nameIdentifier": "460622", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kurano, Mieko"}], "nameIdentifiers": [{"nameIdentifier": "460623", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ota, Syuya"}], "nameIdentifiers": [{"nameIdentifier": "460624", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ideguchi, Yusuke"}], "nameIdentifiers": [{"nameIdentifier": "460625", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasebe, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "460626", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogura, Kouichi"}], "nameIdentifiers": [{"nameIdentifier": "460627", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460628", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "仲 秀一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460629", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 仲宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460630", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川嶋 元", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460631", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蔵野 美恵子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460632", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "太田 周也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460633", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井手口 悠介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460634", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46254", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-01-17"}, "publish_date": "2012-01-17", "publish_status": "0", "recid": "46254", "relation": {}, "relation_version_is_last": true, "title": ["Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique"], "weko_shared_id": -1}
Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique
https://repo.qst.go.jp/records/46254
https://repo.qst.go.jp/records/46254e6489d3f-45db-4c6d-89dd-5bc84616bbd7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-01-17 | |||||
タイトル | ||||||
タイトル | Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kodaira, Satoshi
× Kodaira, Satoshi× Naka, Shuichiro× Yasuda, Nakahiro× Kawashima, Hajime× Kurano, Mieko× Ota, Syuya× Ideguchi, Yusuke× Hasebe, Nobuyuki× Ogura, Kouichi× 小平 聡× 仲 秀一郎× 安田 仲宏× 川嶋 元× 蔵野 美恵子× 太田 周也× 井手口 悠介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We verified that the two-step etching method of the combination of pre-etching with PEW (Potassium hydroxide + Ethanol + Water) solution and post-etching with NaOH solution makes drastic improvement of charge resolution for high Z/b particles (Z: nuclear charge, b: velocity) in CR-39 nuclear track detectors. Detectors were exposed to several heavy ions from Ne to Kr with the energies of <500 MeV/n at HIMAC (Heavy Ion Medical Accelerator in Chiba). The optimum etching conditions were determined to be a preetching of PEW solution with concentration of 60 wt% of ethanol for 40 min and a post-etching of 7N NaOH for 12 h. This resulted in a charge resolution for Kr (Z/b~60) of 0.18 c.u. (charge units). The Z/b detection threshold was increased as a function of ethanol concentration in PEW pre-etching solutions. We found that the two-step etching method would be useful technique for the precise charge identification by a single track measurement. The 60 wt% ethanol concentration in PEW would be adequate selection for the purpose of trans-iron nuclei measurement discriminating abundant light nuclei in galactic cosmic rays. |
|||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section B 巻 274, p. 36-41, 発行日 2012-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X |