WEKO3
アイテム
{"_buckets": {"deposit": "df3d89c0-34d5-41a6-89fc-1af0a3367b5a"}, "_deposit": {"created_by": 1, "id": "46222", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46222"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046222", "sets": ["1"]}, "author_link": ["460277", "460281", "460265", "460282", "460271", "460267", "460269", "460278", "460268", "460264", "460272", "460266", "460274", "460279", "460275", "460276", "460280", "460270", "460273"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "607", "bibliographicPageStart": "597", "bibliographicVolumeNumber": "80", "bibliographic_titles": [{"bibliographic_title": "International Journal of Radiation Oncology Biology Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PURPOSE: We compared four-dimensional (4D) layer-stacking and conventional carbon ion beam distribution in the treatment of lung cancer between ungated and gated respiratory strategies using 4DCT data sets.\n\\nMETHODS AND MATERIALS: Twenty lung patients underwent 4DCT imaging under free-breathing conditions. Using planning target volumes (PTVs) at respective respiratory phases, two types of compensating bolus were designed, a full single respiratory cycle for the ungated strategy and an approximately 30% duty cycle for the exhalation-gated strategy. Beams were delivered to the PTVs for the ungated and gated strategies, PTV(ungated) and PTV(gated), respectively, which were calculated by combining the respective PTV(Tn)s by layer-stacking and conventional irradiation. Carbon ion beam dose distribution was calculated as a function of respiratory phase by applying a compensating bolus to 4DCT. Accumulated dose distributions were calculated by applying deformable registration.\n\\nRESULTS: With the ungated strategy, accumulated dose distributions were satisfactorily provided to the PTV, with D95 values for layer-stacking and conventional irradiation of 94.0% and 96.2%, respectively. V20 for the lung and Dmax for the spinal cord were lower with layer-stacking than with conventional irradiation, whereas Dmax for the skin (14.1 GyE) was significantly lower (21.9 GyE). In addition, dose conformation to the GTV/PTV with layer-stacking irradiation was better with the gated than with the ungated strategy.\n\\nCONCLUSIONS: Gated layer-stacking irradiation allows the delivery of a carbon ion beam to a moving target without significant degradation of dose conformity or the development of hot spots", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0360-3016", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "460264", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "460265", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Asakura, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "460266", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Gregory, Sharp"}], "nameIdentifiers": [{"nameIdentifier": "460267", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kumagai, Motoki"}], "nameIdentifiers": [{"nameIdentifier": "460268", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Dobashi, Suguru"}], "nameIdentifiers": [{"nameIdentifier": "460269", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakajima, Mio"}], "nameIdentifiers": [{"nameIdentifier": "460270", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Naoyoshi"}], "nameIdentifiers": [{"nameIdentifier": "460271", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kandatsu, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "460272", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Baba, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "460273", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460274", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "兼松 伸幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460275", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "浅倉 裕史", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460276", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "熊谷 始紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460277", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土橋 卓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460278", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中嶋 美緒", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460279", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本 直敬", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460281", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "馬場 雅行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460282", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Four-dimensional Lung Treatment Planning in Layer-stacking Carbon Ion Beam Treatment: Comparison of Layer-stacking and Conventional Ungated/Gated Irradiation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Four-dimensional Lung Treatment Planning in Layer-stacking Carbon Ion Beam Treatment: Comparison of Layer-stacking and Conventional Ungated/Gated Irradiation"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46222", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-12-15"}, "publish_date": "2011-12-15", "publish_status": "0", "recid": "46222", "relation": {}, "relation_version_is_last": true, "title": ["Four-dimensional Lung Treatment Planning in Layer-stacking Carbon Ion Beam Treatment: Comparison of Layer-stacking and Conventional Ungated/Gated Irradiation"], "weko_shared_id": -1}
Four-dimensional Lung Treatment Planning in Layer-stacking Carbon Ion Beam Treatment: Comparison of Layer-stacking and Conventional Ungated/Gated Irradiation
https://repo.qst.go.jp/records/46222
https://repo.qst.go.jp/records/4622276a28a2a-4629-46ca-84a6-7bb15949b682
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-12-15 | |||||
タイトル | ||||||
タイトル | Four-dimensional Lung Treatment Planning in Layer-stacking Carbon Ion Beam Treatment: Comparison of Layer-stacking and Conventional Ungated/Gated Irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Kanematsu, Nobuyuki× Asakura, Hiroshi× Gregory, Sharp× Kumagai, Motoki× Dobashi, Suguru× Nakajima, Mio× Yamamoto, Naoyoshi× Kandatsu, Susumu× Baba, Masayuki× 森 慎一郎× 兼松 伸幸× 浅倉 裕史× 熊谷 始紀× 土橋 卓× 中嶋 美緒× 山本 直敬× 神立 進× 馬場 雅行 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: We compared four-dimensional (4D) layer-stacking and conventional carbon ion beam distribution in the treatment of lung cancer between ungated and gated respiratory strategies using 4DCT data sets. \nMETHODS AND MATERIALS: Twenty lung patients underwent 4DCT imaging under free-breathing conditions. Using planning target volumes (PTVs) at respective respiratory phases, two types of compensating bolus were designed, a full single respiratory cycle for the ungated strategy and an approximately 30% duty cycle for the exhalation-gated strategy. Beams were delivered to the PTVs for the ungated and gated strategies, PTV(ungated) and PTV(gated), respectively, which were calculated by combining the respective PTV(Tn)s by layer-stacking and conventional irradiation. Carbon ion beam dose distribution was calculated as a function of respiratory phase by applying a compensating bolus to 4DCT. Accumulated dose distributions were calculated by applying deformable registration. \nRESULTS: With the ungated strategy, accumulated dose distributions were satisfactorily provided to the PTV, with D95 values for layer-stacking and conventional irradiation of 94.0% and 96.2%, respectively. V20 for the lung and Dmax for the spinal cord were lower with layer-stacking than with conventional irradiation, whereas Dmax for the skin (14.1 GyE) was significantly lower (21.9 GyE). In addition, dose conformation to the GTV/PTV with layer-stacking irradiation was better with the gated than with the ungated strategy. \nCONCLUSIONS: Gated layer-stacking irradiation allows the delivery of a carbon ion beam to a moving target without significant degradation of dose conformity or the development of hot spots |
|||||
書誌情報 |
International Journal of Radiation Oncology Biology Physics 巻 80, 号 2, p. 597-607, 発行日 2011-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0360-3016 |