WEKO3
アイテム
{"_buckets": {"deposit": "94e6b808-73e7-422f-b514-58f73ac56db8"}, "_deposit": {"created_by": 1, "id": "46216", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46216"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046216", "sets": ["1"]}, "author_link": ["460195", "460202", "460192", "460191", "460193", "460190", "460204", "460196", "460194", "460189", "460200", "460201", "460197", "460199", "460203", "460198"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "1785", "bibliographicPageStart": "1782", "bibliographicVolumeNumber": "46", "bibliographic_titles": [{"bibliographic_title": "Radiation Measurements"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The two-step etching method using PEW (Potassium hydroxide + Ethanol + Water) and NaOH solutions was applied to the control of the response of CR-39 plastic nuclear track detectors for the measurement of high LET (linear energy transfer) particles. CR-39 detectors were exposed to several heavy ion beams covering the LET_H2O range of 30-750 keV/um from HIMAC (Heavy Ion Medical Accelerator in Chiba) at NIRS (National Institute of Radiological Sciences), Japan. The detectors were pre-etched in PEW solutions with 3 different ethanol concentrations at the temperature of 70 degC for 30-60 min. Then, the detectors were post-etched in 7N NaOH solution at the same temperature for 4-28 h. We found that the response curves and the detection thresholds of the detectors smoothly shifted to higher LET regions as the ethanol concentration increases in PEW solution.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1350-4487", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kodaira, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "460189", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Nakahiro"}], "nameIdentifiers": [{"nameIdentifier": "460190", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawashima, Hajime"}], "nameIdentifiers": [{"nameIdentifier": "460191", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kurano, Mieko"}], "nameIdentifiers": [{"nameIdentifier": "460192", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Naka, Shuichiro"}], "nameIdentifiers": [{"nameIdentifier": "460193", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ota, Syuya"}], "nameIdentifiers": [{"nameIdentifier": "460194", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ideguchi, Yusuke"}], "nameIdentifiers": [{"nameIdentifier": "460195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasebe, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "460196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogura, Kouichi"}], "nameIdentifiers": [{"nameIdentifier": "460197", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460198", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 仲宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川嶋 元", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蔵野 美恵子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "仲 秀一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "太田 周也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井手口 悠介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "460204", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46216", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-11-25"}, "publish_date": "2011-11-25", "publish_status": "0", "recid": "46216", "relation": {}, "relation_version_is_last": true, "title": ["Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles"], "weko_shared_id": -1}
Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles
https://repo.qst.go.jp/records/46216
https://repo.qst.go.jp/records/4621609b93f18-8a02-4727-820f-bac4a77d2d63
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-11-25 | |||||
タイトル | ||||||
タイトル | Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kodaira, Satoshi
× Kodaira, Satoshi× Yasuda, Nakahiro× Kawashima, Hajime× Kurano, Mieko× Naka, Shuichiro× Ota, Syuya× Ideguchi, Yusuke× Hasebe, Nobuyuki× Ogura, Kouichi× 小平 聡× 安田 仲宏× 川嶋 元× 蔵野 美恵子× 仲 秀一郎× 太田 周也× 井手口 悠介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The two-step etching method using PEW (Potassium hydroxide + Ethanol + Water) and NaOH solutions was applied to the control of the response of CR-39 plastic nuclear track detectors for the measurement of high LET (linear energy transfer) particles. CR-39 detectors were exposed to several heavy ion beams covering the LET_H2O range of 30-750 keV/um from HIMAC (Heavy Ion Medical Accelerator in Chiba) at NIRS (National Institute of Radiological Sciences), Japan. The detectors were pre-etched in PEW solutions with 3 different ethanol concentrations at the temperature of 70 degC for 30-60 min. Then, the detectors were post-etched in 7N NaOH solution at the same temperature for 4-28 h. We found that the response curves and the detection thresholds of the detectors smoothly shifted to higher LET regions as the ethanol concentration increases in PEW solution. | |||||
書誌情報 |
Radiation Measurements 巻 46, 号 12, p. 1782-1785, 発行日 2011-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1350-4487 |