{"_buckets": {"deposit": "296bec59-d812-414f-8d2f-e54ed4fef760"}, "_deposit": {"created_by": 1, "id": "46160", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46160"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046160", "sets": ["1"]}, "author_link": ["459614", "459616", "459613", "459617", "459615"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2122", "bibliographicPageEnd": "2856", "bibliographicPageStart": "2847", "bibliographicVolumeNumber": "466", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the Royal Society. Series A"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This study demonstrates that the energy resolution of a newly developed 100 per cent pure polyvinyltoluene (PVT) plate allows its use as a base material for a plastic scintillator. The energy resolution, which is a key element for high-performance radiation detectors, was \u0026Delta;E/E=8.41\u0026plusmn;0.07% (full width at half maximum (FWHM)) for 976 keV K-line conversion electrons from a 207Bi source. On the basis of results from 207Bi and 137Cs sources, the observed energy resolution of the PVT plate, \u0026Delta;E/E=8.2/E1/2% (FWHM), was slightly better than that of a typical plastic scintillator (BC-408), \u0026Delta;E/E=8.7/E1/2% (FWHM), with E in units of MeV. These results prompted us to search for other new base materials for plastic scintillators. In this study, we examined polyethylene terephthalate (PET) bottles, a common source of domestic plastic waste. We demonstrated that a lump of heat-proof PET bottles is fluorescent; moreover, there is excellent compatibility of the fluorescence with the quantum efficiency of typical photomultiplier tubes. This inexpensive source of plastic appears suitable for radiation measurements and as a base material for plastic scintillators. Future studies on the radiation response of plastics should lead to the development of higher performance and more eco-friendly radiation detectors.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1098/rspa.2010.0118", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://rspa.royalsocietypublishing.org/content/466/2122/2847.abstract"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://rspa.royalsocietypublishing.org/content/466/2122/2847.abstract", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1364-5021", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakamura, Hidehito"}], "nameIdentifiers": [{"nameIdentifier": "459613", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "459614", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hazama, Ryuta"}], "nameIdentifiers": [{"nameIdentifier": "459615", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 秀仁", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "459616", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "459617", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Radiation measurements with heat-proof polyethylene terephthalate bottles", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Radiation measurements with heat-proof polyethylene terephthalate bottles"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46160", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-08-16"}, "publish_date": "2011-08-16", "publish_status": "0", "recid": "46160", "relation": {}, "relation_version_is_last": true, "title": ["Radiation measurements with heat-proof polyethylene terephthalate bottles"], "weko_shared_id": -1}
Radiation measurements with heat-proof polyethylene terephthalate bottles
https://repo.qst.go.jp/records/46160
https://repo.qst.go.jp/records/46160f2307b80-8773-487b-8267-c11665079af4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-08-16 | |||||
タイトル | ||||||
タイトル | Radiation measurements with heat-proof polyethylene terephthalate bottles | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nakamura, Hidehito
× Nakamura, Hidehito× Kitamura, Hisashi× Hazama, Ryuta× 中村 秀仁× 北村 尚 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This study demonstrates that the energy resolution of a newly developed 100 per cent pure polyvinyltoluene (PVT) plate allows its use as a base material for a plastic scintillator. The energy resolution, which is a key element for high-performance radiation detectors, was ΔE/E=8.41±0.07% (full width at half maximum (FWHM)) for 976 keV K-line conversion electrons from a 207Bi source. On the basis of results from 207Bi and 137Cs sources, the observed energy resolution of the PVT plate, ΔE/E=8.2/E1/2% (FWHM), was slightly better than that of a typical plastic scintillator (BC-408), ΔE/E=8.7/E1/2% (FWHM), with E in units of MeV. These results prompted us to search for other new base materials for plastic scintillators. In this study, we examined polyethylene terephthalate (PET) bottles, a common source of domestic plastic waste. We demonstrated that a lump of heat-proof PET bottles is fluorescent; moreover, there is excellent compatibility of the fluorescence with the quantum efficiency of typical photomultiplier tubes. This inexpensive source of plastic appears suitable for radiation measurements and as a base material for plastic scintillators. Future studies on the radiation response of plastics should lead to the development of higher performance and more eco-friendly radiation detectors. | |||||
書誌情報 |
Proceedings of the Royal Society. Series A 巻 466, 号 2122, p. 2847-2856, 発行日 2010-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1364-5021 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1098/rspa.2010.0118 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://rspa.royalsocietypublishing.org/content/466/2122/2847.abstract | |||||
関連名称 | http://rspa.royalsocietypublishing.org/content/466/2122/2847.abstract |