WEKO3
アイテム
{"_buckets": {"deposit": "b7710e6c-6688-40b5-97b5-54a179abac39"}, "_deposit": {"created_by": 1, "id": "46110", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46110"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046110", "sets": ["1"]}, "author_link": ["459065", "459061", "459060", "459066", "459063", "459062", "459058", "459059", "459064"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1/3", "bibliographicPageEnd": "310", "bibliographicPageStart": "307", "bibliographicVolumeNumber": "146", "bibliographic_titles": [{"bibliographic_title": "Radiation Protection Dosimetry"}]}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1093/rpd/ncr177", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Radiation Protection Dosimetry (2011)"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "Radiation Protection Dosimetry (2011)", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0144-8420", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Zheng, Jian"}], "nameIdentifiers": [{"nameIdentifier": "459058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhang, Yongsan"}], "nameIdentifiers": [{"nameIdentifier": "459059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Masatoshi"}], "nameIdentifiers": [{"nameIdentifier": "459060", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wu, Fengchang"}], "nameIdentifiers": [{"nameIdentifier": "459061", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Igarashi, Yasuto"}], "nameIdentifiers": [{"nameIdentifier": "459062", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirose, Katsumi"}], "nameIdentifiers": [{"nameIdentifier": "459063", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鄭 建", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "459064", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 永三", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "459065", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 正俊", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "459066", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Determination of Pu isotopes and Am-241 in a reference fallout material using SF-ICP-MS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Determination of Pu isotopes and Am-241 in a reference fallout material using SF-ICP-MS"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46110", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-06-15"}, "publish_date": "2011-06-15", "publish_status": "0", "recid": "46110", "relation": {}, "relation_version_is_last": true, "title": ["Determination of Pu isotopes and Am-241 in a reference fallout material using SF-ICP-MS"], "weko_shared_id": -1}
Determination of Pu isotopes and Am-241 in a reference fallout material using SF-ICP-MS
https://repo.qst.go.jp/records/46110
https://repo.qst.go.jp/records/46110513362f6-f87d-423c-a993-0689cc8c6085
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-06-15 | |||||
タイトル | ||||||
タイトル | Determination of Pu isotopes and Am-241 in a reference fallout material using SF-ICP-MS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Zheng, Jian
× Zheng, Jian× Zhang, Yongsan× Yamada, Masatoshi× Wu, Fengchang× Igarashi, Yasuto× Hirose, Katsumi× 鄭 建× 張 永三× 山田 正俊 |
|||||
書誌情報 |
Radiation Protection Dosimetry 巻 146, 号 1/3, p. 307-310, 発行日 2011-04 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0144-8420 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/ncr177 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | Radiation Protection Dosimetry (2011) | |||||
関連名称 | Radiation Protection Dosimetry (2011) |