WEKO3
アイテム
{"_buckets": {"deposit": "f1216035-4781-46e5-bddb-82c090f122d2"}, "_deposit": {"created_by": 1, "id": "45824", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45824"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045824", "sets": ["1"]}, "author_link": ["455667", "455662", "455656", "455660", "455655", "455671", "455668", "455657", "455659", "455673", "455670", "455666", "455653", "455665", "455652", "455661", "455674", "455654", "455672", "455664", "455658", "455669", "455663"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "02A327-3", "bibliographicPageStart": "02A327-1", "bibliographicVolumeNumber": "81", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; this prototype meanwhile produced over 1 emA of C4+ using C2H2 gas (660 W and 40 kV). The beam intensity of C4+ was 600 e\u0026#61549;A with CH4 gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 e\u0026#61549;A.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.3273055", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Muramatsu, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "455652", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitagawa, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "455653", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Drentje, Arne"}], "nameIdentifiers": [{"nameIdentifier": "455654", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hojo, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "455655", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueda, Takamasa"}], "nameIdentifiers": [{"nameIdentifier": "455656", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyazaki, Hirohumi"}], "nameIdentifiers": [{"nameIdentifier": "455657", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yusa, Ken"}], "nameIdentifiers": [{"nameIdentifier": "455658", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashiro, Mutsumi"}], "nameIdentifiers": [{"nameIdentifier": "455659", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Torikai, Kota"}], "nameIdentifiers": [{"nameIdentifier": "455660", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakama, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "455661", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "455662", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "455663", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455664", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北川 敦志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455665", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Arne Drentje", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455666", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條 悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455667", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田 隆正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455668", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遊佐 顕", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455669", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田代 睦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455670", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鳥飼 幸太", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455671", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂間 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455672", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455673", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 聰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455674", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45824", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-06-16"}, "publish_date": "2010-06-16", "publish_status": "0", "recid": "45824", "relation": {}, "relation_version_is_last": true, "title": ["The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University"], "weko_shared_id": -1}
The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University
https://repo.qst.go.jp/records/45824
https://repo.qst.go.jp/records/458242e3e1b50-6929-48cd-a928-6603c83e20f7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-06-16 | |||||
タイトル | ||||||
タイトル | The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Muramatsu, Masayuki
× Muramatsu, Masayuki× Kitagawa, Atsushi× Drentje, Arne× Hojo, Satoru× Ueda, Takamasa× Miyazaki, Hirohumi× Yusa, Ken× Tashiro, Mutsumi× Torikai, Kota× Sakama, Makoto× Kanai, Tatsuaki× Yamada, Satoru× 村松 正幸× 北川 敦志× Arne Drentje× 北條 悟× 上田 隆正× 遊佐 顕× 田代 睦× 鳥飼 幸太× 坂間 誠× 金井 達明× 山田 聰 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; this prototype meanwhile produced over 1 emA of C4+ using C2H2 gas (660 W and 40 kV). The beam intensity of C4+ was 600 eA with CH4 gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 eA. | |||||
書誌情報 |
Review of Scientific Instruments 巻 81, 号 2, p. 02A327-1-02A327-3, 発行日 2010-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-6748 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.3273055 |