量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum and Radiological Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Quality Assurance in the Prospective Multi-institutional Trial on Definitive Radiotherapy Using High-dose-rate Intracavitary Bracheytherapy for Uterine Cervical Cancer: The Individual Case Review
利用統計を見る
Objective: To assess compliance with the radiotherapy protocol of a multi-institutional prospective study (JAROG0401/JROSG04-2), which investigated the efficacy and toxicity of definitive radiotherapy using high-dose-rate intracavitary brachytherapy (HDR-ICBT) for early-stage uterine cervical cancer patients.
\nMethods: Individual case reviews (ICRs) were performed on all 60 study participants. Radiotherapy data were submitted to the quality assurance (QA) committee, which performed ICRs on 16 QA items according to previously selected criteria. The items focused on quality of external beam radiotherapy (EBRT), HDR-ICBT and both. Each item was determined to be either acceptable or a deviation. The QA committee performed ICR three times as planned, two during the patient accrual and the final one just after the final patient accrued. The QA results of the first and second reviews were reported back to the investigators after each ICR.
\nResults: In 40 cases (67%), all 16 QA items were classified as acceptable. One deviation was found in 16 cases, two deviations were identified in 3 cases and three deviations were noted in 1 case. The most frequently observed deviation was missing the rules for determining point A (10 cases). The items described by quantitative values, such as prescribed doses, certain time intervals and overall treatment time, were well followed. The proportion of deviations gradually decreased during the ICR process.
\nConclusions: The present ICR demonstrated the favorable radiotherapy compliance with the JAROG0401/JROSG04-2 protocol. The QA process using ICRs can potentially be used to improve the quality of radiotherapy, including HDR-ICBT in the multi-institutional prospective studies for cervical cancer.