量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
The characteristics of a radiation detector fabricated with stacks of piezoelectric lead zirconate titanate (PZT) elements were studied by irradiating it with a 400 MeV/n xenon (Xe) beam for various beam pulse durations. This detector is referred to as the multilayered detector (MD). To understand the production mechanism behind the output voltage obtained from the MD, measurement of the spatial distribution of the output signals generated in the MD was attempted. It was found that the amplitude observed was dependent on the number of Xe ions per unit time and the amount of ionization loss energy of Xe ions in PZT.