WEKO3
アイテム
{"_buckets": {"deposit": "6067b27e-eade-4455-a7fc-7f6811549bc7"}, "_deposit": {"created_by": 1, "id": "45709", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45709"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045709", "sets": ["1"]}, "author_link": ["454285", "454288", "454284", "454282", "454286", "454283", "454287", "454280", "454281"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "660", "bibliographicPageStart": "655", "bibliographicVolumeNumber": "96", "bibliographic_titles": [{"bibliographic_title": "Health Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Applicability of selected transportable neutron monitors for cosmic radiation measurement in aircraft was examined; they are (1) a conventional rem meter with polyethylene moderator (NCN1), (2) an extended energy-range rem meter with moderator mixed with tungsten powders (WENDI2) and (3) a recoil-proton scintillation rem meter (PRESCILA). Excellent agreement between measured and calculated values were found in the WENDI2, whereas the observations of NCN1 were about half of the calculated H*(10) values and those of PRESCILA were much higher than predicted values.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0017-9078", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yasuda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "454280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yajima, Kazuaki"}], "nameIdentifiers": [{"nameIdentifier": "454281", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takada, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "454282", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Tatsuhiko"}], "nameIdentifiers": [{"nameIdentifier": "454283", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "454284", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田 浩志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454285", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢島 千秋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454286", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 真志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454287", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 尚司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454288", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Responses of selected neutron monitors to cosmic radiation at aviation altitudes", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Responses of selected neutron monitors to cosmic radiation at aviation altitudes"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45709", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-01-04"}, "publish_date": "2010-01-04", "publish_status": "0", "recid": "45709", "relation": {}, "relation_version_is_last": true, "title": ["Responses of selected neutron monitors to cosmic radiation at aviation altitudes"], "weko_shared_id": -1}
Responses of selected neutron monitors to cosmic radiation at aviation altitudes
https://repo.qst.go.jp/records/45709
https://repo.qst.go.jp/records/45709d7b70b1b-6374-4e54-86d8-36d603189a32
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-01-04 | |||||
タイトル | ||||||
タイトル | Responses of selected neutron monitors to cosmic radiation at aviation altitudes | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yasuda, Hiroshi
× Yasuda, Hiroshi× Yajima, Kazuaki× Takada, Masashi× Sato, Tatsuhiko× Nakamura, Takashi× 保田 浩志× 矢島 千秋× 高田 真志× 中村 尚司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Applicability of selected transportable neutron monitors for cosmic radiation measurement in aircraft was examined; they are (1) a conventional rem meter with polyethylene moderator (NCN1), (2) an extended energy-range rem meter with moderator mixed with tungsten powders (WENDI2) and (3) a recoil-proton scintillation rem meter (PRESCILA). Excellent agreement between measured and calculated values were found in the WENDI2, whereas the observations of NCN1 were about half of the calculated H*(10) values and those of PRESCILA were much higher than predicted values. | |||||
書誌情報 |
Health Physics 巻 96, 号 6, p. 655-660, 発行日 2009-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0017-9078 |