WEKO3
アイテム
{"_buckets": {"deposit": "7e242bc9-5aed-4c35-8f8f-e1872d363145"}, "_deposit": {"created_by": 1, "id": "45620", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45620"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045620", "sets": ["1"]}, "author_link": ["453363", "453359", "453361", "453360", "453358", "453362", "453364"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "Supplement A", "bibliographicPageEnd": "A80", "bibliographicPageStart": "A75", "bibliographicVolumeNumber": "48", "bibliographic_titles": [{"bibliographic_title": "Journal of Radiation Research"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "harged particle therapy depends on biological information for the dose prescription. Relative biological effectiveness or RBE for this requirement could basically be provided by experimental data. As RBE values of protons and carbon ions depend on several factors such as cell/tissue type, biological endpoint, dose and fractionation schedule, a single RBE value could not deal with all different radiosensitivities. However, any biological model with accurate reproducibility is useful for comparing biological effectiveness between different facilities. We used mouse gut crypt survivals as endpoint, and compared the cell killing efficiency of proton beams at three Japanese facilities. Three Linac X-ray machines with 4 and 6 MeV were used as reference beams, and there was only a small variation (coefficient of variance \u003c 2%) in biological effectiveness among them. The RBE values of protons relative to Linac X-rays ranged from 1.0 to 1.11 at the middle of a 6-cm SOBP (spread-out Bragg peak) and from 0.96 to 1.01 at the entrance plateau. The coefficient of variance for protons ranged between 4.0 and 5.1%. The biological comparison of carbon ions showed fairly good agreement in that the difference in biological effectiveness between NIRS/HIMAC and GSI/SIS was 1% for three positions within the 6-cm SOBP. The coefficient of variance was \u003c 1.7, \u003c 0.6 and \u003c 1.6% for proximal, middle and distal SOBP, respectively. We conclude that the inter-institutional variation of biological effectiveness is smaller for carbon ions than protons, and that beam-spreading methods of carbon ions do not critically influence gut crypt survival.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0449-3060", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Uzawa, Akiko"}], "nameIdentifiers": [{"nameIdentifier": "453358", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ando, Koichi"}], "nameIdentifiers": [{"nameIdentifier": "453359", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furusawa, Yoshiya"}], "nameIdentifiers": [{"nameIdentifier": "453360", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "453361", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鵜澤 玲子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "453362", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安藤 興一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "453363", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤 佳也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "453364", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45620", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-08-27"}, "publish_date": "2009-08-27", "publish_status": "0", "recid": "45620", "relation": {}, "relation_version_is_last": true, "title": ["Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams"], "weko_shared_id": -1}
Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams
https://repo.qst.go.jp/records/45620
https://repo.qst.go.jp/records/4562078982657-902d-4e55-acae-f760bc1ca7ab
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-08-27 | |||||
タイトル | ||||||
タイトル | Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Uzawa, Akiko
× Uzawa, Akiko× Ando, Koichi× Furusawa, Yoshiya× et.al× 鵜澤 玲子× 安藤 興一× 古澤 佳也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | harged particle therapy depends on biological information for the dose prescription. Relative biological effectiveness or RBE for this requirement could basically be provided by experimental data. As RBE values of protons and carbon ions depend on several factors such as cell/tissue type, biological endpoint, dose and fractionation schedule, a single RBE value could not deal with all different radiosensitivities. However, any biological model with accurate reproducibility is useful for comparing biological effectiveness between different facilities. We used mouse gut crypt survivals as endpoint, and compared the cell killing efficiency of proton beams at three Japanese facilities. Three Linac X-ray machines with 4 and 6 MeV were used as reference beams, and there was only a small variation (coefficient of variance < 2%) in biological effectiveness among them. The RBE values of protons relative to Linac X-rays ranged from 1.0 to 1.11 at the middle of a 6-cm SOBP (spread-out Bragg peak) and from 0.96 to 1.01 at the entrance plateau. The coefficient of variance for protons ranged between 4.0 and 5.1%. The biological comparison of carbon ions showed fairly good agreement in that the difference in biological effectiveness between NIRS/HIMAC and GSI/SIS was 1% for three positions within the 6-cm SOBP. The coefficient of variance was < 1.7, < 0.6 and < 1.6% for proximal, middle and distal SOBP, respectively. We conclude that the inter-institutional variation of biological effectiveness is smaller for carbon ions than protons, and that beam-spreading methods of carbon ions do not critically influence gut crypt survival. | |||||
書誌情報 |
Journal of Radiation Research 巻 48, 号 Supplement A, p. A75-A80, 発行日 2007-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0449-3060 |