{"_buckets": {"deposit": "ee95a9bf-203b-46ab-bf75-9cb10fe531be"}, "_deposit": {"created_by": 1, "id": "45456", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45456"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045456", "sets": ["1"]}, "author_link": ["451637", "451639", "451636", "451640", "451641", "451635", "451638", "451632", "451633", "451634"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "3258", "bibliographicPageStart": "3252", "bibliographicVolumeNumber": "35", "bibliographic_titles": [{"bibliographic_title": "Medical Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A multi-slit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an X-ray energy of about 100 keV. It consists of 30 slits that are 25 um high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25um-thick polyimide sheets that were separated by 175um-thick tungsten sheets. We measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a CCD camera and found that the ratios of the dose at the center of a microbeam to that at mid-positions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code Phits.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0094-2405", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ohno, Yumiko"}], "nameIdentifiers": [{"nameIdentifier": "451632", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Torikoshi, Masami"}], "nameIdentifiers": [{"nameIdentifier": "451633", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Masao"}], "nameIdentifiers": [{"nameIdentifier": "451634", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Umetani, Keiji"}], "nameIdentifiers": [{"nameIdentifier": "451635", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uesugi, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "451636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yagi, Naoto"}], "nameIdentifiers": [{"nameIdentifier": "451637", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "451638", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大野 由美子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451639", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "取越 正己", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451640", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 雅雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451641", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45456", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-03-26"}, "publish_date": "2009-03-26", "publish_status": "0", "recid": "45456", "relation": {}, "relation_version_is_last": true, "title": ["Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy"], "weko_shared_id": -1}
Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy
https://repo.qst.go.jp/records/45456
https://repo.qst.go.jp/records/45456eea9a76b-195f-4f20-b953-0875517328ba
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-26 | |||||
タイトル | ||||||
タイトル | Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ohno, Yumiko
× Ohno, Yumiko× Torikoshi, Masami× Suzuki, Masao× Umetani, Keiji× Uesugi, Kentaro× Yagi, Naoto× et.al× 大野 由美子× 取越 正己× 鈴木 雅雄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A multi-slit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an X-ray energy of about 100 keV. It consists of 30 slits that are 25 um high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25um-thick polyimide sheets that were separated by 175um-thick tungsten sheets. We measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a CCD camera and found that the ratios of the dose at the center of a microbeam to that at mid-positions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code Phits. | |||||
書誌情報 |
Medical Physics 巻 35, 号 7, p. 3252-3258, 発行日 2008-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 |