WEKO3
アイテム
{"_buckets": {"deposit": "f61dc990-063b-4219-9910-e09c77ef14a4"}, "_deposit": {"created_by": 1, "id": "45351", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45351"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045351", "sets": ["1"]}, "author_link": ["450511", "450508", "450510", "450513", "450512", "450509"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "814", "bibliographicPageStart": "811", "bibliographicVolumeNumber": "170", "bibliographic_titles": [{"bibliographic_title": "Radiation Research"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new method for calibration was developed that takes the\nenergy deposited by radioisotope sources into account; it was\nvalidated with a plastic scintillation plate using a 207Bi source.\nThe energy deposits of the conversion electrons in the 207Bi\nsource led to an energy difference of a few keV for the 976\nkeV monoenergetic peak. Calibration with high accuracy is\nessential to estimate radiation doses as well as to evaluate detector\nperformance. The method will be available not only for\nuse in scintillation detectors but also for other detectors.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0033-7587", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakamura, Hidehito"}], "nameIdentifiers": [{"nameIdentifier": "450508", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ejiri, Hiroyasu"}], "nameIdentifiers": [{"nameIdentifier": "450509", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "450510", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 秀仁", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450511", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "江尻 宏泰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450512", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450513", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45351", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-12-18"}, "publish_date": "2008-12-18", "publish_status": "0", "recid": "45351", "relation": {}, "relation_version_is_last": true, "title": ["A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources"], "weko_shared_id": -1}
A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources
https://repo.qst.go.jp/records/45351
https://repo.qst.go.jp/records/4535166b9ca17-ae00-482d-a8b6-0629f1e8dca0
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-12-18 | |||||
タイトル | ||||||
タイトル | A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nakamura, Hidehito
× Nakamura, Hidehito× Ejiri, Hiroyasu× Kitamura, Hisashi× 中村 秀仁× 江尻 宏泰× 北村 尚 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new method for calibration was developed that takes the energy deposited by radioisotope sources into account; it was validated with a plastic scintillation plate using a 207Bi source. The energy deposits of the conversion electrons in the 207Bi source led to an energy difference of a few keV for the 976 keV monoenergetic peak. Calibration with high accuracy is essential to estimate radiation doses as well as to evaluate detector performance. The method will be available not only for use in scintillation detectors but also for other detectors. |
|||||
書誌情報 |
Radiation Research 巻 170, 号 6, p. 811-814, 発行日 2008-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0033-7587 |