{"_buckets": {"deposit": "6d4bf654-52f1-4675-88e0-6d0a76f87239"}, "_deposit": {"created_by": 1, "id": "45224", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45224"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045224", "sets": ["1"]}, "author_link": ["449201", "449202", "449203", "449200"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "550", "bibliographicPageStart": "541", "bibliographicVolumeNumber": "64", "bibliographic_titles": [{"bibliographic_title": "Journal of Oceanography"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "241Am is a useful tracer in understanding biogeochemical processes in the marine environment. 241Am also poses a potential radiation threat against human health due to the continuous increase of its concentration in the global environment. We report a rapid analytical method for 241Am in marine sediments using isotope dilution sector-field inductively coupled plasma mass spectrometry (SF-ICP-MS) combined with a high-efficiency sample introduction system (APEX-Q). A selective CaF2 co-precipitation procedure followed by TRU extraction chromatography was employed to effectively remove the major sediment matrix and to pre-concentrate 241Am. We achieved an extremely low detection limit of 0.32 fg/g or 0.041 mBq/g (for 1 gram sediment), which is better than that of alpha spectrometry, and it allowed the accurate determination of 241Am in low-level marine sediment samples. The accuracy and precision of the developed analytical method was evaluated using a laboratory prepared Am isotope standard solution and Ocean Sediment reference material (IAEA-368) and the results were satisfactory. For sediment samples, overall, chemical recoveries varied from 60 - 90 %. The developed method was applied to the study of 241Am depth distribution in Sagami Bay, Japan, in which we observed different depth profiles between 241Am activity and 239+240Pu activity.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0916-8370", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Zheng, Jian"}], "nameIdentifiers": [{"nameIdentifier": "449200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Masatoshi"}], "nameIdentifiers": [{"nameIdentifier": "449201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鄭 建", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "449202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 正俊", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "449203", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45224", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-07-16"}, "publish_date": "2008-07-16", "publish_status": "0", "recid": "45224", "relation": {}, "relation_version_is_last": true, "title": ["Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan"], "weko_shared_id": -1}
Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan
https://repo.qst.go.jp/records/45224
https://repo.qst.go.jp/records/45224e3268638-8990-4eb1-b20e-0e560648d5a6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-07-16 | |||||
タイトル | ||||||
タイトル | Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Zheng, Jian
× Zheng, Jian× Yamada, Masatoshi× 鄭 建× 山田 正俊 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 241Am is a useful tracer in understanding biogeochemical processes in the marine environment. 241Am also poses a potential radiation threat against human health due to the continuous increase of its concentration in the global environment. We report a rapid analytical method for 241Am in marine sediments using isotope dilution sector-field inductively coupled plasma mass spectrometry (SF-ICP-MS) combined with a high-efficiency sample introduction system (APEX-Q). A selective CaF2 co-precipitation procedure followed by TRU extraction chromatography was employed to effectively remove the major sediment matrix and to pre-concentrate 241Am. We achieved an extremely low detection limit of 0.32 fg/g or 0.041 mBq/g (for 1 gram sediment), which is better than that of alpha spectrometry, and it allowed the accurate determination of 241Am in low-level marine sediment samples. The accuracy and precision of the developed analytical method was evaluated using a laboratory prepared Am isotope standard solution and Ocean Sediment reference material (IAEA-368) and the results were satisfactory. For sediment samples, overall, chemical recoveries varied from 60 - 90 %. The developed method was applied to the study of 241Am depth distribution in Sagami Bay, Japan, in which we observed different depth profiles between 241Am activity and 239+240Pu activity. | |||||
書誌情報 |
Journal of Oceanography 巻 64, 号 4, p. 541-550, 発行日 2008-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0916-8370 |