WEKO3
アイテム
{"_buckets": {"deposit": "c9023819-5e20-442b-945f-bd1808f5ea37"}, "_deposit": {"created_by": 1, "id": "45203", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45203"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045203", "sets": ["1"]}, "author_link": ["449006", "449010", "449007", "449004", "449003", "449008", "449009", "449005"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "3706", "bibliographicPageStart": "3701", "bibliographicVolumeNumber": "53", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Nuclear Science"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We describe microdosimetric measurements and simulations with Geant4 and FLUKA Monte Carlo codes in silicon and tissue. Analyses of deposited energy in sensitive volumes of some micrometers were carried out after exposure to heavy ion radiation", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9499", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Beck, Peter"}], "nameIdentifiers": [{"nameIdentifier": "449003", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wind, Michael"}], "nameIdentifiers": [{"nameIdentifier": "449004", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Rollet, Sofia"}], "nameIdentifiers": [{"nameIdentifier": "449005", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Latocha, Marcin"}], "nameIdentifiers": [{"nameIdentifier": "449006", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Bock, Florian"}], "nameIdentifiers": [{"nameIdentifier": "449007", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Bock, H"}], "nameIdentifiers": [{"nameIdentifier": "449008", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchihori, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "449009", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "449010", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45203", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-06-18"}, "publish_date": "2008-06-18", "publish_status": "0", "recid": "45203", "relation": {}, "relation_version_is_last": true, "title": ["Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue"], "weko_shared_id": -1}
Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue
https://repo.qst.go.jp/records/45203
https://repo.qst.go.jp/records/45203a25a91b0-fbf2-4942-962c-0b57dabe8ae7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-06-18 | |||||
タイトル | ||||||
タイトル | Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Beck, Peter
× Beck, Peter× Wind, Michael× Rollet, Sofia× Latocha, Marcin× Bock, Florian× Bock, H× Uchihori, Yukio× 内堀 幸夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We describe microdosimetric measurements and simulations with Geant4 and FLUKA Monte Carlo codes in silicon and tissue. Analyses of deposited energy in sensitive volumes of some micrometers were carried out after exposure to heavy ion radiation | |||||
書誌情報 |
IEEE Transactions on Nuclear Science 巻 53, 号 6, p. 3701-3706, 発行日 2006-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9499 |