WEKO3
アイテム
{"_buckets": {"deposit": "a5ac1df5-64da-4a2c-9ebd-b1e96afc8d05"}, "_deposit": {"created_by": 1, "id": "45193", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45193"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045193", "sets": ["1"]}, "author_link": ["448902", "448898", "448903", "448905", "448906", "448908", "448904", "448910", "448901", "448900", "448899", "448907", "448909"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4A", "bibliographicPageEnd": "1706", "bibliographicPageStart": "1704", "bibliographicVolumeNumber": "46", "bibliographic_titles": [{"bibliographic_title": "Japanese Journal of Applied Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The characteristics of piezoelectric lead-zirconate-titanate (PZT) detectors were studied by directly irradiating them with a 400 MeV/n Xe beam. The sensitivity of a multilayered detector was discussed in comparison with that of a monolayered detector. It was found that the sensitivity of the detectors depended on their structure.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0021-4922", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takechi, Seiji"}], "nameIdentifiers": [{"nameIdentifier": "448898", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Onishi, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "448899", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Minami, Shigeyuki"}], "nameIdentifiers": [{"nameIdentifier": "448900", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyachi, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "448901", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujii, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "448902", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasebe, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "448903", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mori, Kunishiro"}], "nameIdentifiers": [{"nameIdentifier": "448904", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibata, Hiromi"}], "nameIdentifiers": [{"nameIdentifier": "448905", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murakami, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "448906", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchihori, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "448907", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okada, Nagaya"}], "nameIdentifiers": [{"nameIdentifier": "448908", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448909", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448910", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Comparison between two piezoelectric lead-zirconate-titanate detectors bombarded with high-energy xenon beam", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparison between two piezoelectric lead-zirconate-titanate detectors bombarded with high-energy xenon beam"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45193", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-06-11"}, "publish_date": "2008-06-11", "publish_status": "0", "recid": "45193", "relation": {}, "relation_version_is_last": true, "title": ["Comparison between two piezoelectric lead-zirconate-titanate detectors bombarded with high-energy xenon beam"], "weko_shared_id": -1}
Comparison between two piezoelectric lead-zirconate-titanate detectors bombarded with high-energy xenon beam
https://repo.qst.go.jp/records/45193
https://repo.qst.go.jp/records/451937c475c30-a53c-4ec9-a5e0-3be7f44c2a65
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-06-11 | |||||
タイトル | ||||||
タイトル | Comparison between two piezoelectric lead-zirconate-titanate detectors bombarded with high-energy xenon beam | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Takechi, Seiji
× Takechi, Seiji× Onishi, Toshiyuki× Minami, Shigeyuki× Miyachi, Takashi× Fujii, Masayuki× Hasebe, Nobuyuki× Mori, Kunishiro× Shibata, Hiromi× Murakami, Takeshi× Uchihori, Yukio× Okada, Nagaya× 村上 健× 内堀 幸夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The characteristics of piezoelectric lead-zirconate-titanate (PZT) detectors were studied by directly irradiating them with a 400 MeV/n Xe beam. The sensitivity of a multilayered detector was discussed in comparison with that of a monolayered detector. It was found that the sensitivity of the detectors depended on their structure. | |||||
書誌情報 |
Japanese Journal of Applied Physics 巻 46, 号 4A, p. 1704-1706, 発行日 2007-04 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0021-4922 |