{"_buckets": {"deposit": "3f805a57-963f-4a58-a8bf-9c240abbd4a4"}, "_deposit": {"created_by": 1, "id": "45106", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45106"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045106", "sets": ["1"]}, "author_link": ["447932", "447926", "447931", "447927", "447930", "447934", "447924", "447933", "447928", "447929", "447925"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "196", "bibliographicPageStart": "189", "bibliographicVolumeNumber": "21", "bibliographic_titles": [{"bibliographic_title": "Annals of Nuclear Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of this study was to compare the diagnostic performance of positron emission tomography (PET) alone, computed tomography (CT) alone, side-by-side reading, and fused images for restaging or follow-up of patients with malignant lymphoma. METHODS: Fifty patients with histologically confirmed non-Hodgkin lymphoma underwent an (18)fluoro-2-deoxyglucose (FDG)-PET scan, followed by a CT scan. CT alone, PET alone, side-by-side reading, and fused images were interpreted separately and visually using a five-point grading scale for the following eight regions: cervical, supraclavicular, axillary, mediastinal, para-aortic to iliac, mesenteric, inguinal, and extra-nodal. Diagnostic accuracy was compared on the basis of the final diagnoses determined by histological confirmation and/or clinical course. RESULTS: For all regions combined, the interpretation of PET alone (sensitivity = 86.1%, specificity = 99.4%, accuracy = 91.0%), side-by-side reading (96.0%, 99.4%, 98.9%), and fused images (98.0%, 99.4%, 99.2%) yielded significantly higher diagnostic performance than that of CT alone (59.4%, 96.1%, 91.0%; P \u003c 0.001). The cervical, supraclavicular, and extra-nodal regions were more accurately diagnosed with PET (P \u003c 0.05), whereas the para-aortic to iliac regions were diagnosed more accurately with side-by-side reading and fused images than with CT alone or PET alone (P \u003c 0.05). CONCLUSIONS: Although fused images are clinically valuable, side-by-side reading showed equivalent performance, whereas the interpretation of PET alone yielded reasonably high diagnostic performance for restaging or follow-up of patients with malignant lymphoma.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-7187", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nogami, Munenobu"}], "nameIdentifiers": [{"nameIdentifier": "447924", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamoto, Yuji"}], "nameIdentifiers": [{"nameIdentifier": "447925", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Setsu"}], "nameIdentifiers": [{"nameIdentifier": "447926", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukushima, Kazuto"}], "nameIdentifiers": [{"nameIdentifier": "447927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okada, Tomohisa"}], "nameIdentifiers": [{"nameIdentifier": "447928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saga, Tsuneo"}], "nameIdentifiers": [{"nameIdentifier": "447929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Higashi, Tatsuya"}], "nameIdentifiers": [{"nameIdentifier": "447930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Senda, Michio"}], "nameIdentifiers": [{"nameIdentifier": "447931", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsui, Toshimitsu"}], "nameIdentifiers": [{"nameIdentifier": "447932", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sugimura, Kazuro"}], "nameIdentifiers": [{"nameIdentifier": "447933", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "447934", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Diagnostic performance of CT, PET, side-by-side, and fused image interpretations for restaging of non-Hodgkin lymphoma.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Diagnostic performance of CT, PET, side-by-side, and fused image interpretations for restaging of non-Hodgkin lymphoma."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45106", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-03-04"}, "publish_date": "2008-03-04", "publish_status": "0", "recid": "45106", "relation": {}, "relation_version_is_last": true, "title": ["Diagnostic performance of CT, PET, side-by-side, and fused image interpretations for restaging of non-Hodgkin lymphoma."], "weko_shared_id": -1}
Diagnostic performance of CT, PET, side-by-side, and fused image interpretations for restaging of non-Hodgkin lymphoma.
https://repo.qst.go.jp/records/45106
https://repo.qst.go.jp/records/45106f85a7a91-04da-4e0d-b0d7-4c15065ea1be
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-03-04 | |||||
タイトル | ||||||
タイトル | Diagnostic performance of CT, PET, side-by-side, and fused image interpretations for restaging of non-Hodgkin lymphoma. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nogami, Munenobu
× Nogami, Munenobu× Nakamoto, Yuji× Sakamoto, Setsu× Fukushima, Kazuto× Okada, Tomohisa× Saga, Tsuneo× Higashi, Tatsuya× Senda, Michio× Matsui, Toshimitsu× Sugimura, Kazuro× 佐賀 恒夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to compare the diagnostic performance of positron emission tomography (PET) alone, computed tomography (CT) alone, side-by-side reading, and fused images for restaging or follow-up of patients with malignant lymphoma. METHODS: Fifty patients with histologically confirmed non-Hodgkin lymphoma underwent an (18)fluoro-2-deoxyglucose (FDG)-PET scan, followed by a CT scan. CT alone, PET alone, side-by-side reading, and fused images were interpreted separately and visually using a five-point grading scale for the following eight regions: cervical, supraclavicular, axillary, mediastinal, para-aortic to iliac, mesenteric, inguinal, and extra-nodal. Diagnostic accuracy was compared on the basis of the final diagnoses determined by histological confirmation and/or clinical course. RESULTS: For all regions combined, the interpretation of PET alone (sensitivity = 86.1%, specificity = 99.4%, accuracy = 91.0%), side-by-side reading (96.0%, 99.4%, 98.9%), and fused images (98.0%, 99.4%, 99.2%) yielded significantly higher diagnostic performance than that of CT alone (59.4%, 96.1%, 91.0%; P < 0.001). The cervical, supraclavicular, and extra-nodal regions were more accurately diagnosed with PET (P < 0.05), whereas the para-aortic to iliac regions were diagnosed more accurately with side-by-side reading and fused images than with CT alone or PET alone (P < 0.05). CONCLUSIONS: Although fused images are clinically valuable, side-by-side reading showed equivalent performance, whereas the interpretation of PET alone yielded reasonably high diagnostic performance for restaging or follow-up of patients with malignant lymphoma. | |||||
書誌情報 |
Annals of Nuclear Medicine 巻 21, 号 4, p. 189-196, 発行日 2007-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 |