WEKO3
アイテム
{"_buckets": {"deposit": "ce4eed54-c254-4c9c-ba2e-199efe3b32ca"}, "_deposit": {"created_by": 1, "id": "45105", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45105"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045105", "sets": ["1"]}, "author_link": ["447918", "447923", "447920", "447919", "447916", "447914", "447913", "447915", "447921", "447922", "447917", "447912"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "1006", "bibliographicPageStart": "1000", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "Journal of Magnetic Resonance Imaging : JMRI"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PURPOSE: To evaluate the impact of magnetic resonance cholangiopancreatography (MRCP) imaging at 1.5T and 3.0T on image quality. MATERIALS AND METHODS: Fourteen volunteers were examined at both 1.5T and 3.0T using MRCP imaging performed with a breath-held two-dimensional (2D) half-Fourier acquired single-shot turbo spin-echo (HASTE) thick-slab sequence, a free-breathing navigator-triggered three-dimensional (3D) turbo spin-echo (TSE) sequence with prospective acquisition correction, and a heavily T2-weighted (T2W) sequence with breath-held multislice HASTE. All images were scored for visualization of the biliary and pancreatic ducts, severity of artifacts, image noise, and overall image quality. RESULTS: MRCP imaging at 3.0T yielded a significant improvement in overall image quality compared to 1.5T. We found a trend for superior visualization of the biliary and pancreatic ducts at 3.0T. Heavily T2W imaging with thin sections (1.4 mm) at 3.0T provided diagnostic images and better visualization of the biliary and pancreatic ducts than heavily T2W imaging with standard sections (2.8 mm) at 3.0T. CONCLUSION: Our experience suggests that MRCP imaging at 3.0T has the potential to provide excellent images. High-resolution heavily T2W imaging with a small voxel size (1.3 x 1.3 x 1.4 mm) at 3.0T can provide diagnostic images and allow evaluation of small pathologies of the bile and pancreatic ducts, which 1.5T MRI cannot sufficiently visualize.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1053-1807", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Isoda, Hiroyoshi"}], "nameIdentifiers": [{"nameIdentifier": "447912", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kataoka, Masako"}], "nameIdentifiers": [{"nameIdentifier": "447913", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maetani, Youji"}], "nameIdentifiers": [{"nameIdentifier": "447914", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kido, Aki"}], "nameIdentifiers": [{"nameIdentifier": "447915", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Umeoka, Shigeaki"}], "nameIdentifiers": [{"nameIdentifier": "447916", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamai, Ken"}], "nameIdentifiers": [{"nameIdentifier": "447917", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koyama, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "447918", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamoto, Yuji"}], "nameIdentifiers": [{"nameIdentifier": "447919", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miki, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "447920", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saga, Tsuneo"}], "nameIdentifiers": [{"nameIdentifier": "447921", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Togashi, Kaori"}], "nameIdentifiers": [{"nameIdentifier": "447922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "447923", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "MRCP imaging at 3.0 T vs. 1.5 T: Preliminary experience in healthy volunteers.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "MRCP imaging at 3.0 T vs. 1.5 T: Preliminary experience in healthy volunteers."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45105", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-03-04"}, "publish_date": "2008-03-04", "publish_status": "0", "recid": "45105", "relation": {}, "relation_version_is_last": true, "title": ["MRCP imaging at 3.0 T vs. 1.5 T: Preliminary experience in healthy volunteers."], "weko_shared_id": -1}
MRCP imaging at 3.0 T vs. 1.5 T: Preliminary experience in healthy volunteers.
https://repo.qst.go.jp/records/45105
https://repo.qst.go.jp/records/45105d3809f3a-490c-4d08-b260-e76de6661ae9
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-03-04 | |||||
タイトル | ||||||
タイトル | MRCP imaging at 3.0 T vs. 1.5 T: Preliminary experience in healthy volunteers. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Isoda, Hiroyoshi
× Isoda, Hiroyoshi× Kataoka, Masako× Maetani, Youji× Kido, Aki× Umeoka, Shigeaki× Tamai, Ken× Koyama, Takashi× Nakamoto, Yuji× Miki, Yukio× Saga, Tsuneo× Togashi, Kaori× 佐賀 恒夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: To evaluate the impact of magnetic resonance cholangiopancreatography (MRCP) imaging at 1.5T and 3.0T on image quality. MATERIALS AND METHODS: Fourteen volunteers were examined at both 1.5T and 3.0T using MRCP imaging performed with a breath-held two-dimensional (2D) half-Fourier acquired single-shot turbo spin-echo (HASTE) thick-slab sequence, a free-breathing navigator-triggered three-dimensional (3D) turbo spin-echo (TSE) sequence with prospective acquisition correction, and a heavily T2-weighted (T2W) sequence with breath-held multislice HASTE. All images were scored for visualization of the biliary and pancreatic ducts, severity of artifacts, image noise, and overall image quality. RESULTS: MRCP imaging at 3.0T yielded a significant improvement in overall image quality compared to 1.5T. We found a trend for superior visualization of the biliary and pancreatic ducts at 3.0T. Heavily T2W imaging with thin sections (1.4 mm) at 3.0T provided diagnostic images and better visualization of the biliary and pancreatic ducts than heavily T2W imaging with standard sections (2.8 mm) at 3.0T. CONCLUSION: Our experience suggests that MRCP imaging at 3.0T has the potential to provide excellent images. High-resolution heavily T2W imaging with a small voxel size (1.3 x 1.3 x 1.4 mm) at 3.0T can provide diagnostic images and allow evaluation of small pathologies of the bile and pancreatic ducts, which 1.5T MRI cannot sufficiently visualize. | |||||
書誌情報 |
Journal of Magnetic Resonance Imaging : JMRI 巻 25, 号 5, p. 1000-1006, 発行日 2007-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1053-1807 |