WEKO3
アイテム
{"_buckets": {"deposit": "b89d3140-a92f-4373-8905-11f1d116e1e2"}, "_deposit": {"created_by": 1, "id": "45034", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45034"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045034", "sets": ["1"]}, "author_link": ["447211", "447212", "447207", "447206", "447205", "447210", "447208", "447209"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "4022", "bibliographicPageStart": "4016", "bibliographicVolumeNumber": "34", "bibliographic_titles": [{"bibliographic_title": "Medical Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To estimate the physical dose at the center of spread-out Bragg peaks (SOBP) for various conditions of the irradiation system, a semi-empirical approach was applied. The dose at the center of the SOBP depends on the field size because of large-angle scattering particles in the water phantom. For a small field of 5x5 cm2, the dose was reduced to 99.2, 97.5, and 96.5 % of the dose used for the open field in the case of 290, 350, and 400 MeV/n carbon beams, respectively. Based on the three-Gaussian form of the lateral dose distributions of the carbon pencil beam, which has previously been shown to be effective for describing scattered carbon beams, we reconstructed the dose distributions of the SOBP beam. The reconstructed lateral dose distribution reproduced the measured lateral dose distributions very well. The field-size dependencies calculated using the reconstructed lateral dose distribution of the therapeutic carbon beam agreed with the measured dose dependency very well. The reconstructed beam was also used for irregularly shaped fields. The resultant dose distribution agreed with the measured dose distribution. The reconstructed beams were found to be applicable to the treatment-planning system.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1118/1.2779126", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0094-2405", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kusano, Yohsuke"}], "nameIdentifiers": [{"nameIdentifier": "447205", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "447206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yonai, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "447207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Komori, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "447208", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "447209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "447210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "米内 俊祐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "447211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小森 雅孝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "447212", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Field-size dependence of doses of therapeutic carbon beams", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Field-size dependence of doses of therapeutic carbon beams"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45034", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-11-28"}, "publish_date": "2007-11-28", "publish_status": "0", "recid": "45034", "relation": {}, "relation_version_is_last": true, "title": ["Field-size dependence of doses of therapeutic carbon beams"], "weko_shared_id": -1}
Field-size dependence of doses of therapeutic carbon beams
https://repo.qst.go.jp/records/45034
https://repo.qst.go.jp/records/45034dda49517-1c28-4d2c-b9d2-b5aa665c95eb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-11-28 | |||||
タイトル | ||||||
タイトル | Field-size dependence of doses of therapeutic carbon beams | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kusano, Yohsuke
× Kusano, Yohsuke× Kanai, Tatsuaki× Yonai, Shunsuke× Komori, Masataka× et.al× 金井 達明× 米内 俊祐× 小森 雅孝 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To estimate the physical dose at the center of spread-out Bragg peaks (SOBP) for various conditions of the irradiation system, a semi-empirical approach was applied. The dose at the center of the SOBP depends on the field size because of large-angle scattering particles in the water phantom. For a small field of 5x5 cm2, the dose was reduced to 99.2, 97.5, and 96.5 % of the dose used for the open field in the case of 290, 350, and 400 MeV/n carbon beams, respectively. Based on the three-Gaussian form of the lateral dose distributions of the carbon pencil beam, which has previously been shown to be effective for describing scattered carbon beams, we reconstructed the dose distributions of the SOBP beam. The reconstructed lateral dose distribution reproduced the measured lateral dose distributions very well. The field-size dependencies calculated using the reconstructed lateral dose distribution of the therapeutic carbon beam agreed with the measured dose dependency very well. The reconstructed beam was also used for irregularly shaped fields. The resultant dose distribution agreed with the measured dose distribution. The reconstructed beams were found to be applicable to the treatment-planning system. | |||||
書誌情報 |
Medical Physics 巻 34, 号 10, p. 4016-4022, 発行日 2007-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1118/1.2779126 |