WEKO3
アイテム
{"_buckets": {"deposit": "0f9bcacd-4528-4636-98f7-3d42c8f9f49c"}, "_deposit": {"created_by": 1, "id": "44832", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44832"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044832", "sets": ["1"]}, "author_link": ["445238", "445231", "445228", "445236", "445234", "445233", "445237", "445239", "445232", "445230", "445235", "445229"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "2108", "bibliographicPageStart": "2100", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "European Radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We evaluated Feldkamp artifacts, which are specific to cone-beam CT, in phantom and clinical studies using the 256 multi-detector-row CT (256MDCT), and compared the reconstruction accuracy of axial and helical scans.\nImage noise, slice sensitivity profile (SSP) and artifacts with the 256MDCT were evaluated using a phantom and the results were compared to those with a 64MDCT. We also examined chest and abdomen scans produced with the 256MDCT in volunteers.\nFor the axial scan, Feldkamp artifacts were visualized as high-frequency streak-like artifacts that are oriented horizontally at the edge of the scan region in the phantom study. Similar results were obtained with the volunteers in soft-tissue regions near either bony structures or air pockets. Feldkamp artifacts with the 256MDCT can lead to misdiagnosis if not correctly identified and minimized via helical scanning. Image noise was less for axial than helical scans, while SSP was better with helical than axial scans. \nFeldkamp artifacts observed in the 256MDCT images, however, did not generally affect the interpretation of images. The 256MDCT promises more accurate diagnosis, and will provide volumetric cine images of wider cranio-caudal coverage, enabling new applications of CT.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0938-7994", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "445228", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "445229", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "445230", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsunoo, Takanori"}], "nameIdentifiers": [{"nameIdentifier": "445231", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kandatsu, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "445232", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanada, Shuji"}], "nameIdentifiers": [{"nameIdentifier": "445233", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445234", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445235", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445236", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "角尾 卓紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445237", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445238", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "棚田 修二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445239", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Properties of the prototype 256-row (cone beam) CT scanner", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Properties of the prototype 256-row (cone beam) CT scanner"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44832", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-04-19"}, "publish_date": "2007-04-19", "publish_status": "0", "recid": "44832", "relation": {}, "relation_version_is_last": true, "title": ["Properties of the prototype 256-row (cone beam) CT scanner"], "weko_shared_id": -1}
Properties of the prototype 256-row (cone beam) CT scanner
https://repo.qst.go.jp/records/44832
https://repo.qst.go.jp/records/44832758a74b4-d2d4-4687-8340-52c4fba14bd7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-04-19 | |||||
タイトル | ||||||
タイトル | Properties of the prototype 256-row (cone beam) CT scanner | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Endo, Masahiro× Obata, Takayuki× Tsunoo, Takanori× Kandatsu, Susumu× Tanada, Shuji× 森 慎一郎× 遠藤 真広× 小畠 隆行× 角尾 卓紀× 神立 進× 棚田 修二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated Feldkamp artifacts, which are specific to cone-beam CT, in phantom and clinical studies using the 256 multi-detector-row CT (256MDCT), and compared the reconstruction accuracy of axial and helical scans. Image noise, slice sensitivity profile (SSP) and artifacts with the 256MDCT were evaluated using a phantom and the results were compared to those with a 64MDCT. We also examined chest and abdomen scans produced with the 256MDCT in volunteers. For the axial scan, Feldkamp artifacts were visualized as high-frequency streak-like artifacts that are oriented horizontally at the edge of the scan region in the phantom study. Similar results were obtained with the volunteers in soft-tissue regions near either bony structures or air pockets. Feldkamp artifacts with the 256MDCT can lead to misdiagnosis if not correctly identified and minimized via helical scanning. Image noise was less for axial than helical scans, while SSP was better with helical than axial scans. Feldkamp artifacts observed in the 256MDCT images, however, did not generally affect the interpretation of images. The 256MDCT promises more accurate diagnosis, and will provide volumetric cine images of wider cranio-caudal coverage, enabling new applications of CT. |
|||||
書誌情報 |
European Radiology 巻 16, 号 9, p. 2100-2108, 発行日 2006-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0938-7994 |