{"_buckets": {"deposit": "874c676e-0f71-48fc-a787-f5a1ff4761fa"}, "_deposit": {"created_by": 1, "id": "44826", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44826"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044826", "sets": ["1"]}, "author_link": ["445180", "445185", "445183", "445174", "445181", "445179", "445184", "445177", "445182", "445188", "445187", "445189", "445178", "445175", "445176", "445186"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "294", "bibliographicPageStart": "289", "bibliographicVolumeNumber": "59", "bibliographic_titles": [{"bibliographic_title": "European Journal of Radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In cone-beam geometry, image quality may be degraded or artifacts may occur if the cone angle is substantially wide. This is because a cone-beam scan along a circular orbit does not collect the complete set of data required to make an exact reconstruction of all volumetric data. To increase temporal resolution and thus image quality in cone-beam geometry, Silver proposed the new half-scan algorithm (NHS-FDK), which extends Parker\u0027s weighting function (HS-FDK) by utilizing a larger range up to 2pi. Here, we evaluated these algorithms for hepatic contrast-enhanced CT in cine scan mode using a 256-detector row CT. The full-scan (FS-FDK) images show uniform distribution of the image noise and CT-number uniformity. Image noise and CT-number uniformity with HS-FDK and NHS-FDK images follow the initial projection angle. HS-FDK images therefore have more changeable higher intensity (brighter) and a lower intensity (darker) areas than respective FS-FDK and NHS-FDK images. We concluded that, considering the trade-off between image quality and temporal resolution, the NHS-FDK algorithm is useful in volumetric cine imaging for the abdomen.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0720-048X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "445174", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "445175", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "445176", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kishimoto, Riwa"}], "nameIdentifiers": [{"nameIdentifier": "445177", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katou, Hirotoshi"}], "nameIdentifiers": [{"nameIdentifier": "445178", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kandatsu, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "445179", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsujii, Hirohiko"}], "nameIdentifiers": [{"nameIdentifier": "445180", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanada, Shuji"}], "nameIdentifiers": [{"nameIdentifier": "445181", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445182", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445183", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445184", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岸本 理和", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445185", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤 博敏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445186", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445187", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井 博彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445188", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "棚田 修二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445189", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: Case study for hepatic volumetric cine imaging", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: Case study for hepatic volumetric cine imaging"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44826", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-04-06"}, "publish_date": "2007-04-06", "publish_status": "0", "recid": "44826", "relation": {}, "relation_version_is_last": true, "title": ["Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: Case study for hepatic volumetric cine imaging"], "weko_shared_id": -1}
Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: Case study for hepatic volumetric cine imaging
https://repo.qst.go.jp/records/44826
https://repo.qst.go.jp/records/448265a5da98a-9620-4738-ba6b-13cab4bd6ab6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-04-06 | |||||
タイトル | ||||||
タイトル | Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: Case study for hepatic volumetric cine imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Endo, Masahiro× Obata, Takayuki× Kishimoto, Riwa× Katou, Hirotoshi× Kandatsu, Susumu× Tsujii, Hirohiko× Tanada, Shuji× 森 慎一郎× 遠藤 真広× 小畠 隆行× 岸本 理和× 加藤 博敏× 神立 進× 辻井 博彦× 棚田 修二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In cone-beam geometry, image quality may be degraded or artifacts may occur if the cone angle is substantially wide. This is because a cone-beam scan along a circular orbit does not collect the complete set of data required to make an exact reconstruction of all volumetric data. To increase temporal resolution and thus image quality in cone-beam geometry, Silver proposed the new half-scan algorithm (NHS-FDK), which extends Parker's weighting function (HS-FDK) by utilizing a larger range up to 2pi. Here, we evaluated these algorithms for hepatic contrast-enhanced CT in cine scan mode using a 256-detector row CT. The full-scan (FS-FDK) images show uniform distribution of the image noise and CT-number uniformity. Image noise and CT-number uniformity with HS-FDK and NHS-FDK images follow the initial projection angle. HS-FDK images therefore have more changeable higher intensity (brighter) and a lower intensity (darker) areas than respective FS-FDK and NHS-FDK images. We concluded that, considering the trade-off between image quality and temporal resolution, the NHS-FDK algorithm is useful in volumetric cine imaging for the abdomen. | |||||
書誌情報 |
European Journal of Radiology 巻 59, p. 289-294, 発行日 2006-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0720-048X |