WEKO3
アイテム
{"_buckets": {"deposit": "729768fa-8ed5-4ab5-a960-1db2552b0859"}, "_deposit": {"created_by": 1, "id": "44752", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44752"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044752", "sets": ["1"]}, "author_link": ["444345", "444344", "444352", "444353", "444350", "444346", "444355", "444354", "444343", "444341", "444351", "444356", "444348", "444342", "444349", "444347"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "638", "bibliographicPageStart": "629", "bibliographicVolumeNumber": "166", "bibliographic_titles": [{"bibliographic_title": "Radiation Research"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The microdosimetric spectra for high-energy beams of photons and proton, helium, carbon, neon, silicon and iron ions (LET = 0.5-880 keV/um) were measured with a spherical-walled tissue-equivalent proportional counter at various depths in a plastic phantom. Survival curves for human tumor cells were also obtained under the same conditions. Then the survival curves were compared with those estimated by a microdosimetric model based on the spectra and the biological parameters for each cell line. The estimated alpha terms of the liner-quadratic model with a fixed beta value reproduced the experimental results for cell irradiation for ion beams with LETs of less than 450 keV/um, except in the region near the distal peak.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0033-7587", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kase, Yuuki"}], "nameIdentifiers": [{"nameIdentifier": "444341", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "444342", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Yoshitaka"}], "nameIdentifiers": [{"nameIdentifier": "444343", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furusawa, Yoshiya"}], "nameIdentifiers": [{"nameIdentifier": "444344", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okamoto, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "444345", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Asaba, Tooru"}], "nameIdentifiers": [{"nameIdentifier": "444346", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakama, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "444347", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinoda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "444348", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加瀬 優紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444349", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444350", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 孔貴", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444351", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤 佳也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡本 裕之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "浅羽 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂間 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444355", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "篠田 浩司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444356", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Microdosimetric Measurements and Estimation of Human Cell Survival for Heavy-Ion Beams", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Microdosimetric Measurements and Estimation of Human Cell Survival for Heavy-Ion Beams"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44752", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-12-27"}, "publish_date": "2006-12-27", "publish_status": "0", "recid": "44752", "relation": {}, "relation_version_is_last": true, "title": ["Microdosimetric Measurements and Estimation of Human Cell Survival for Heavy-Ion Beams"], "weko_shared_id": -1}
Microdosimetric Measurements and Estimation of Human Cell Survival for Heavy-Ion Beams
https://repo.qst.go.jp/records/44752
https://repo.qst.go.jp/records/4475297e9bec9-c0ac-48cc-96f0-cdf64db33757
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-27 | |||||
タイトル | ||||||
タイトル | Microdosimetric Measurements and Estimation of Human Cell Survival for Heavy-Ion Beams | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kase, Yuuki
× Kase, Yuuki× Kanai, Tatsuaki× Matsumoto, Yoshitaka× Furusawa, Yoshiya× Okamoto, Hiroyuki× Asaba, Tooru× Sakama, Makoto× Shinoda, Hiroshi× 加瀬 優紀× 金井 達明× 松本 孔貴× 古澤 佳也× 岡本 裕之× 浅羽 徹× 坂間 誠× 篠田 浩司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The microdosimetric spectra for high-energy beams of photons and proton, helium, carbon, neon, silicon and iron ions (LET = 0.5-880 keV/um) were measured with a spherical-walled tissue-equivalent proportional counter at various depths in a plastic phantom. Survival curves for human tumor cells were also obtained under the same conditions. Then the survival curves were compared with those estimated by a microdosimetric model based on the spectra and the biological parameters for each cell line. The estimated alpha terms of the liner-quadratic model with a fixed beta value reproduced the experimental results for cell irradiation for ion beams with LETs of less than 450 keV/um, except in the region near the distal peak. | |||||
書誌情報 |
Radiation Research 巻 166, 号 4, p. 629-638, 発行日 2006-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0033-7587 |