量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
A low-energy ion decelerator for the acceleration-deceleration system has been designed and installed in the beam-injection line of the NIRS-930 cyclotron in an attempt to increase the beam intensity from the cyclotron. With this acceleration-deceleration system, the beam intensity of C-12(4+) ions at the cyclotron exit has been increased by about five times. The system has an advantage in that it allows us to extract a high-current ion beam from an electron cyclotron resonance ion source because, independently of the injection-energy matching to the cyclotron, a large potential difference can be applied between the source and the extractor. The voltage applied to the extractor is about -12 kV, which is reduced to the ground potential by the decelerator. The electric field distributions in the deceleration system were carefully designed using a three-dimensional field simulator. Design studies of the decelerator as well as the result of a beam test are presented.