量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum and Radiological Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
A compact injector for medical accelerators was designed. The injector consists of a compact Electron-Cyclotron-Resonance Ion Source (ECRIS) and two linacs, which are a Radio-Frequency-Quadrupole (RFQ) linac and an Interdigital H-mode Drift-Tube-Linac
(IH-DTL) having the same operating frequency of 200 MHz. For beam focusing of the IH-DTL, the method of Alternating-Phase-Focusing (APF) was applied. Before constructing the compact injector, a model cavity of the IH-DTL was manufactured, and measurements of the electric-field distributions were performed. The gap-voltage distributions, obtained by integrating the measured electric field, were compared with those calculated using a three-dimensional field solver. The accuracy of the calculated field distributions is discussed. Finally, fine adjustments of the gap voltages using inductive tuners are described.