WEKO3
アイテム
{"_buckets": {"deposit": "b96d31c1-75d2-439b-87f2-62653e68a185"}, "_deposit": {"created_by": 1, "id": "44476", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44476"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044476", "sets": ["1"]}, "author_link": ["441985", "441980", "441975", "441977", "441979", "441981", "441974", "441984", "441973", "441982", "441983", "441976", "441978"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1991-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "9", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "5", "bibliographic_titles": [{"bibliographic_title": "Annals of Nuclear Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Data obtained from planar images were used to measure the uptake of monoclonal antibody in organs and tumors. Background counts included in the region of interest were eliminated, and the attenuation of the photons emitted by the radionuclide through the intervening tissues was compensated for. The background counts and the intensity of the attenuation were determined from the results of phantom studies and numerical integration with a personal computer. The quantitative uptake of 111In labeled anti-melanoma Monoclonal Antibody (ZME-018) in a melanoma lesion, the liver, and the bone marrow of a patient was measured by the planar method which we developed.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-7187", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Akiyama, Yoshihisa"}], "nameIdentifiers": [{"nameIdentifier": "441973", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Tooru"}], "nameIdentifiers": [{"nameIdentifier": "441974", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iinuma, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "441975", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ikehira, Hiroo"}], "nameIdentifiers": [{"nameIdentifier": "441976", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukuda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "441977", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tateno, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "441978", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "441979", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "秋山 芳久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441980", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441981", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯沼 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441982", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池平 博夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441983", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田 寛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441984", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野 之男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "441985", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Quantitative measurement of uptake of radiolabeled monoclonal antibody by means of planar data.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Quantitative measurement of uptake of radiolabeled monoclonal antibody by means of planar data."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44476", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-07-19"}, "publish_date": "2006-07-19", "publish_status": "0", "recid": "44476", "relation": {}, "relation_version_is_last": true, "title": ["Quantitative measurement of uptake of radiolabeled monoclonal antibody by means of planar data."], "weko_shared_id": -1}
Quantitative measurement of uptake of radiolabeled monoclonal antibody by means of planar data.
https://repo.qst.go.jp/records/44476
https://repo.qst.go.jp/records/444766afbcce8-6f38-4553-97b4-ab67170b1365
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-07-19 | |||||
タイトル | ||||||
タイトル | Quantitative measurement of uptake of radiolabeled monoclonal antibody by means of planar data. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Akiyama, Yoshihisa
× Akiyama, Yoshihisa× Matsumoto, Tooru× Iinuma, Takeshi× Ikehira, Hiroo× Fukuda, Hiroshi× Tateno, Yukio× et.al× 秋山 芳久× 松本 徹× 飯沼 武× 池平 博夫× 福田 寛× 舘野 之男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Data obtained from planar images were used to measure the uptake of monoclonal antibody in organs and tumors. Background counts included in the region of interest were eliminated, and the attenuation of the photons emitted by the radionuclide through the intervening tissues was compensated for. The background counts and the intensity of the attenuation were determined from the results of phantom studies and numerical integration with a personal computer. The quantitative uptake of 111In labeled anti-melanoma Monoclonal Antibody (ZME-018) in a melanoma lesion, the liver, and the bone marrow of a patient was measured by the planar method which we developed. | |||||
書誌情報 |
Annals of Nuclear Medicine 巻 5, 号 1, p. 1-9, 発行日 1991-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 |