{"_buckets": {"deposit": "7f1ef36c-f5f1-40e7-91c3-f122a4e76983"}, "_deposit": {"created_by": 1, "id": "44349", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44349"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044349", "sets": ["1"]}, "author_link": ["440590", "440585", "440587", "440589", "440592", "440591", "440583", "440586", "440582", "440588", "440584"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "191", "bibliographicPageStart": "186", "bibliographicVolumeNumber": "47", "bibliographic_titles": [{"bibliographic_title": "Acta Radiologica"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To investigate the feasibility of volumetric cine imaging in human cardiac studies, by comparing in vivo and in vitro coronary angiography using a 256-detector row CT without ECG gating.\n\\nMaterial and Methods: The left and right coronary arteries of two domestic pigs were scanned in vivo and in vitro in cine mode using the 256-detector row CT. The device scanned approximately 100 mm in the cranio-caudal direction with one rotation, with a slice thickness of 0.5 mm.\n\\nResults: The coronary arteries could be observed to the third-degree branches in vitro, but could be visualized clearly only to the proximal portion (first- or second-degree branches) in vivo. \n\\nConclusion: Application of cardiac volumetric cine imaging with 256-detector row CT appears a promising means of obtaining diagnostic information and has potential for adoption to human studies.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0284-1851", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "440582", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kondo, Chisato"}], "nameIdentifiers": [{"nameIdentifier": "440583", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "440584", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kusakabe, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "440585", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "440586", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "440587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "近藤 千里", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 直樹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "日下部 正宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440592", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44349", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-24"}, "publish_date": "2006-06-24", "publish_status": "0", "recid": "44349", "relation": {}, "relation_version_is_last": true, "title": ["Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models"], "weko_shared_id": -1}
Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models
https://repo.qst.go.jp/records/44349
https://repo.qst.go.jp/records/44349a674ee20-72c0-40e5-b54e-23d62a6f9109
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-24 | |||||
タイトル | ||||||
タイトル | Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Kondo, Chisato× Suzuki, Naoki× Kusakabe, Masahiro× Endo, Masahiro× et.al× 森 慎一郎× 近藤 千里× 鈴木 直樹× 日下部 正宏× 遠藤 真広 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To investigate the feasibility of volumetric cine imaging in human cardiac studies, by comparing in vivo and in vitro coronary angiography using a 256-detector row CT without ECG gating. \nMaterial and Methods: The left and right coronary arteries of two domestic pigs were scanned in vivo and in vitro in cine mode using the 256-detector row CT. The device scanned approximately 100 mm in the cranio-caudal direction with one rotation, with a slice thickness of 0.5 mm. \nResults: The coronary arteries could be observed to the third-degree branches in vitro, but could be visualized clearly only to the proximal portion (first- or second-degree branches) in vivo. \nConclusion: Application of cardiac volumetric cine imaging with 256-detector row CT appears a promising means of obtaining diagnostic information and has potential for adoption to human studies. |
|||||
書誌情報 |
Acta Radiologica 巻 47, 号 2, p. 186-191, 発行日 2006-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0284-1851 |