{"_buckets": {"deposit": "4d1a915e-3ff5-4ea2-b6cd-e0e1f39b5c0a"}, "_deposit": {"created_by": 1, "id": "44332", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44332"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044332", "sets": ["1"]}, "author_link": ["440372", "440374", "440373", "440375"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "1253", "bibliographicPageStart": "1246", "bibliographicVolumeNumber": "69", "bibliographic_titles": [{"bibliographic_title": "Talanta"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An analytical method for the determination of plutonium concentration and its isotope ratio (240Pu/239Pu) for settling particle samples by inductively coupled plasma mass spectrometry (ICP-MS) is presented. The generally used approach for Pu preconcentration by increasing the amount of samples is not applicable because of the small size of settling particle samples available for the analysis for Pu isotopes. Efforts were made to improve the sensitivity of a sector-field ICP-MS (SF-ICP-MS) and reduce the 238UH+ interference for Pu analysis by combining a high-efficiency sample introduction system (APEX-Q). An extremely low detection limit of 0.07 fg Pu was achieved, which allowed the determination of Pu isotope ratio at femtogram levels. The precision and accuracy of 240Pu/239Pu isotope ratio analysis were carefully examined with a certified Pu isotope standard (NBS-947) and an ocean sediment reference material (IAEA-368). Simple anion-exchange chromatography for the separation and purification of Pu was combined with the APEX-Q/SF-ICP-MS system to determine Pu isotopes in settling particles collected in the East China Sea continental margin. The obtained results supported a previous observation on the lateral transport of Pu containing particles in this continental margin. \n\\nKeywords: Plutonium; isotope ratio; settling particles; ICP-SFMS; marine environment", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0039-9140", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Zheng, Jian"}], "nameIdentifiers": [{"nameIdentifier": "440372", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Masatoshi"}], "nameIdentifiers": [{"nameIdentifier": "440373", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鄭 建", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440374", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 正俊", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440375", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44332", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-23"}, "publish_date": "2006-06-23", "publish_status": "0", "recid": "44332", "relation": {}, "relation_version_is_last": true, "title": ["Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels"], "weko_shared_id": -1}
Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels
https://repo.qst.go.jp/records/44332
https://repo.qst.go.jp/records/44332540e5cfe-39c4-4ccf-b755-dea8696ca3c2
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-23 | |||||
タイトル | ||||||
タイトル | Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Zheng, Jian
× Zheng, Jian× Yamada, Masatoshi× 鄭 建× 山田 正俊 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An analytical method for the determination of plutonium concentration and its isotope ratio (240Pu/239Pu) for settling particle samples by inductively coupled plasma mass spectrometry (ICP-MS) is presented. The generally used approach for Pu preconcentration by increasing the amount of samples is not applicable because of the small size of settling particle samples available for the analysis for Pu isotopes. Efforts were made to improve the sensitivity of a sector-field ICP-MS (SF-ICP-MS) and reduce the 238UH+ interference for Pu analysis by combining a high-efficiency sample introduction system (APEX-Q). An extremely low detection limit of 0.07 fg Pu was achieved, which allowed the determination of Pu isotope ratio at femtogram levels. The precision and accuracy of 240Pu/239Pu isotope ratio analysis were carefully examined with a certified Pu isotope standard (NBS-947) and an ocean sediment reference material (IAEA-368). Simple anion-exchange chromatography for the separation and purification of Pu was combined with the APEX-Q/SF-ICP-MS system to determine Pu isotopes in settling particles collected in the East China Sea continental margin. The obtained results supported a previous observation on the lateral transport of Pu containing particles in this continental margin. \nKeywords: Plutonium; isotope ratio; settling particles; ICP-SFMS; marine environment |
|||||
書誌情報 |
Talanta 巻 69, 号 5, p. 1246-1253, 発行日 2006-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0039-9140 |